Yamaha D24 Owner's Manual - Page 162

Duplicating MO Disks, Setting the SCSI ID of the Internal MO Drive, Hookup

Page 162 highlights

162 Chapter 14-SCSI & External Disk Drives Duplicating MO Disks MO disks can be duplicated using two D24s and the Duplicate function. In addition to duplicating disks, this is a convenient way to back up MO disks. The source and destination MO disks must be of the same capacity: 230 MB, 540 MB, or 640 MB. You cannot, for example, duplicate a 230 MB disk to a 640 MB disk. The type of disk, however, is not important, so you can duplicate an Overwrite-type MO disk to a normal MO disk and vice versa. Individual projects can be copied between an external disk drive and the internal MO drive using the Backup function. See "Copying Projects Between Disk Drives" on page 164 for more information. Setting the SCSI ID of the Internal MO Drive In order to use the Duplicate function, the internal MO drive of the destination D24 (D24-B) must be set to a higher SCSI ID than the MO drive of the source D24 (D24-A). Since the default SCSI ID for the internal MO drive is 2, you could set the D24-B to SCSI ID 3, 4, or 5, or alternatively set D24-A to SCSI ID 0 or 1 (SCSI IDs 6 and 7 are reserved for other purposes). See "Setting the SCSI ID of the Internal MO Drive" on page 193 for more information. Hookup To hookup the D24s you'll need a 50-pin, half-pitch SCSI cable (pin type). Data is transferred from D24-A to D24-B via the SCSI cable. The MO disk in D24-A is duplicated to the MO disk in D24-B. The internal MO drive of D24-B is set to SCSI ID 3. D24-A OVER -dB 0 2 6 10 12 14 20 18 30 20 42 26 60 READY 1 2 3 4 5 RECORD READY SOLO/ SELECT PEAK HOLD AUTO INPUT ALL INPUT MONITOR SELECT OVER 0 -dB 2 6 12 20 30 42 60 READY 0 0 0 0 0 0 0 0 ABS H M S F YAMAHA D24 LOCK WC INT FS 48K BIT 24 TC MASTER L R 6 7 8 7 8 9 PROJECT SELECT 4 5 6 LOC MEM RECALL FORMAT CHASE 1 2 3 LOC MEM STORE 0/- CANCEL ENTER LOCATE TIME DISPLAY CAPTURE ABS/REL REMAIN VARI SPEED UTILITY SETUP V. TRACK SELECT EDIT UNDO/ REDO JOG ON DIGITAL MULTITRACK RECORDER PROJECT SEARCH LAST REC IN OUT SET AUTO PUNCH RTN TO ZERO ROLL BACK A B REPEAT REHE AB REW FF STOP PLAY REC JOG/DATA SHUTTLE/ CURSOR SCSI port POWER ON OFF 0 10 PHONES LEVEL PHONES The MO disk in D24-A is duplicated on D24-B SCSI cable D24-B SCSI port OVER -dB 0 2 6 10 12 14 20 18 30 20 42 26 60 READY 1 2 3 4 5 RECORD READY SOLO/ SELECT PEAK HOLD AUTO INPUT ALL INPUT MONITOR SELECT OVER 0 -dB 2 6 12 20 30 42 60 READY 0 0 0 0 0 0 0 0 ABS H M S F YAMAHA D24 LOCK WC INT BIT 24 FS 48K TC MASTER L R 6 7 8 7 8 9 PROJECT SELECT 4 5 6 LOC MEM RECALL FORMAT CHASE 1 2 3 LOC MEM STORE 0/- CANCEL ENTER LOCATE TIME DISPLAY CAPTURE ABS/REL REMAIN VARI SPEED UTILITY SETUP V. TRACK SELECT EDIT UNDO/ REDO JOG ON DIGITAL MULTITRACK RECORDER PROJECT SEARCH LAST REC IN OUT SET AUTO PUNCH RTN TO ZERO ROLL BACK A B REPEAT REHE AB REW FF STOP PLAY REC JOG/DATA SHUTTLE/ CURSOR POWER ON OFF 0 10 PHONES LEVEL PHONES SCSI ID settings D24-A MO drive: 2 D24-B MO drive: 3 D24-Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211

162
Chapter 14
SCSI & External Disk Drives
D24—Owner’s Manual
Duplicating MO Disks
MO disks can be duplicated using two D24s and the Duplicate function. In addition to
duplicating disks, this is a convenient way to back up MO disks. The source and desti-
nation MO disks must be of the same capacity: 230 MB, 540 MB, or 640 MB. You can-
not, for example, duplicate a 230 MB disk to a 640 MB disk. The type of disk, however,
is not important, so you can duplicate an Overwrite-type MO disk to a normal MO
disk and vice versa.
Individual projects can be copied between an external disk drive and the internal MO
drive using the Backup function. See “Copying Projects Between Disk Drives” on page
164 for more information.
Setting the SCSI ID of the Internal MO Drive
In order to use the Duplicate function, the internal MO drive of the destination D24
(D24-B) must be set to a higher SCSI ID than the MO drive of the source D24 (D24-A).
Since the default SCSI ID for the internal MO drive is 2, you could set the D24-B to
SCSI ID 3, 4, or 5, or alternatively set D24-A to SCSI ID 0 or 1 (SCSI IDs 6 and 7 are
reserved for other purposes). See “Setting the SCSI ID of the Internal MO Drive” on
page 193 for more information.
Hookup
To hookup the D24s you’ll need a 50-pin, half-pitch SCSI cable (pin type). Data is
transferred from D24-A to D24-B via the SCSI cable. The MO disk in D24-A is dupli-
cated to the MO disk in D24-B. The internal MO drive of D24-B is set to SCSI ID 3.
SCSI cable
SCSI port
SCSI port
00 00 00 00
YAMAHA
D24
LOCK
TIME DISPLAY
CAPTURE
ABS/REL
REMAIN
VARI
SPEED
UTILITY
SETUP
PROJECT
SELECT
LOC MEM
RECALL
LOC MEM
STORE
LOCATE
ENTER
CANCEL
0/-
1
4
7
8
R
7
6
5
4
3
2
1
RECORD
READY
SOLO/
SELECT
MONITOR SELECT
PEAK
HOLD
AUTO
INPUT
ALL
INPUT
FORMAT
CHASE
L
2
5
8
3
6
9
UNDO/
REDO
EDIT
JOG ON
JOG/DATA
SHUTTLE/
CURSOR
PROJECT SEARCH
RTN TO
ZERO
REW
FF
STOP
PLAY
REC
ROLL
BACK
LAST REC
SET
DIGITAL MULTITRACK RECORDER
REPEAT
REHE
PHONES
LEVEL
0
10
ON
POWER
OFF
PHONES
B
A
B
A
AUTO
PUNCH
IN
OUT
INT
24
48K
MASTER
WC
BIT
FS
TC
V.TRACK
SELECT
00 00 00 00
YAMAHA
D24
LOCK
TIME DISPLAY
CAPTURE
ABS/REL
REMAIN
VARI
SPEED
UTILITY
SETUP
PROJECT
SELECT
LOC MEM
RECALL
LOC MEM
STORE
LOCATE
ENTER
CANCEL
0/-
1
4
7
8
R
7
6
5
4
3
2
1
RECORD
READY
SOLO/
SELECT
MONITOR SELECT
PEAK
HOLD
AUTO
INPUT
ALL
INPUT
FORMAT
CHASE
L
2
5
8
3
6
9
UNDO/
REDO
EDIT
JOG ON
JOG/DATA
SHUTTLE/
CURSOR
PROJECT SEARCH
RTN TO
ZERO
REW
FF
STOP
PLAY
REC
ROLL
BACK
LAST REC
SET
DIGITAL MULTITRACK RECORDER
REPEAT
REHE
PHONES
LEVEL
0
10
ON
POWER
OFF
PHONES
B
A
B
A
AUTO
PUNCH
IN
OUT
INT
24
48K
MASTER
WC
BIT
FS
TC
V.TRACK
SELECT
D24-A
The MO disk in D24-A
is duplicated on D24-B
D24-B
SCSI ID settings
D24-A MO drive: 2
D24-B MO drive: 3