Appendix, Setting the SCSI ID of the Internal MO Drive
View all Yamaha D24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 192 highlights
Setting the SCSI ID of the Internal MO Drive 193 Appendix Setting the SCSI ID of the Internal MO Drive Setting the SCSI ID of the internal MO disk drive involves removing the D24's top cover and setting the DIP switch located on the MO drive's circuit board. This procedure should be carried out by a qualified engineer. If in doubt, contact your Yamaha dealer. 1 Remove the top-cover fixing screws (11), as shown here. 2 Remove the top cover. 1 2 3 4567 OFF 3 Using a small flat-bladed screwdriver, or something similar, set DIP switches 1 through 3, as listed below, to achieve the required SCSI ID. 8 SCSI ID 5 4 3 2 (default) 1 0 DIP switch number 1 2 3 ON OFF ON ON OFF OFF OFF ON ON OFF ON OFF OFF OFF ON OFF OFF OFF SCSI IDs 6 and 7 are not listed, since they are reserved for other purposes. D24-Owner's Manual