ZyXEL U-336R User Guide - Page 122

Command, Function and description

Page 122 highlights

Command bit dec hex Function and description Ref. power on 64 40 Profile 2 as active settings after Z2 power on 96 60 Profile 3 as active settings after Z3 power on 128 80 * Factory default as active settings Z4 after power on S16= dec hex Test status register +000 0 0 No test in progress &T0 1 1 Loop-back test in progress &T1 3 3 Local Digital Loop-back test in &T3 process 6 6 Remote Digital Loop-back test &T6 in process 7 7 Remote Digital Loop-back with &T7 self-test in process 8 8 Analog Loop-back with self test &T8 in progress S17= bit dec hex Bit-mapped register +018 0 0 0 Disable secondary channel *S0 (default) 4-1 0-30 0-1E Set leased line transmit power *Pn level from 0 to -15 dBm. (See also S35b3) (Default *P9) 5 0 0 Normal dial (Default) D 32 20 Reverse dial, go on-line in DR answer mode. 7,6 0 0 AT Commands set (Default) *I0 64 40 V.25bis command set *I1 128 80 Dumb mode (no command *I2 108 Status Registers & Result Codes

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161

108
Status Registers & Result Codes
Command
bit
dec
hex
Function and description
Ref.
power on
64
40
Profile 2 as active settings after
power on
Z2
96
60
Profile 3 as active settings after
power on
Z3
128
80 * Factory default as active settings
after power on
Z4
S16=
dec hex
Test status register
+000
0
0
No test in progress
&T0
1
1
Loop-back test in progress
&T1
3
3
Local Digital Loop-back test in
process
&T3
6
6
Remote Digital Loop-back test
in process
&T6
7
7
Remote Digital Loop-back with
self-test in process
&T7
8
8
Analog Loop-back with self test
in progress
&T8
S17=
bit
dec hex
Bit-mapped register
+018
0
0
0
Disable secondary channel
(default)
*S0
4-1 0-30 0-1E Set leased line transmit power
level from 0 to -15 dBm. (See
also S35b3) (Default *P9)
*Pn
5
0
0
Normal dial (Default)
D
32
20
Reverse dial, go on-line in
answer mode.
DR
7,6 0
0
AT Commands set (Default)
*I0
64
40
V.25bis command set
*I1
128 80
Dumb mode (no command
*I2