ZyXEL U-336R User Guide - Page 90

Phase C received EOL alignment

Page 90 highlights

Command +FDT +FEA=n +FIE=n +FIP +FIS=vr,br,wd,l n,df,ec,bf,st +FKS +FLI="string" +FLO=n +FLP=n Value n=0 n=1 n=0 n=1 n=0 n=1 n=2 n=0 n=1 Description document reception Transmit phase C data command: releases the DCE to proceed with negotiation Phase C received EOL alignment parameter Determine that T.4 EOL patterns are bit aligned (as received). Determine that the last received bits of T.4 EOL patterns are byte aligned by the DCE, with necessary zero fill bits inserted. Procedure interrupt parameter Procedure interrupt requests from the remote station are ignored, and not reported to the DTE. Procedure interrupt requests from the remote station are accepted, negotiated and reported using the +FVO response. Initialize facsimile parameters to factory default. Current session parameter. refer to +FDCC Class 2 command in previous section parameter settings. Session termination command. Local ID string parameter. Flow control options: No flow control. Set XON/XOFF software flow control. Set CTS/RTS hardware flow control. Document for polling command: The DTE has no document for polling. Indicated document available for polling. 76 Fax Operation

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161

76
Fax Operation
Command
Value
Description
document reception
+FDT
Transmit phase C data command: releases
the DCE to proceed with
negotiation
+FEA=
n
Phase C received EOL alignment
parameter
n=0
Determine that T.4 EOL patterns are bit
aligned (as received).
n=1
Determine that the last received bits of T.4
EOL patterns are byte aligned by the
DCE, with necessary zero fill bits inserted.
+FIE=
n
Procedure interrupt parameter
n=0
Procedure interrupt requests from the
remote station are ignored, and
not
reported to the DTE.
n=1
Procedure interrupt requests from the
remote station are accepted, negotiated
and reported using the +FVO response.
+FIP
Initialize facsimile parameters to factory
default.
+FIS=
vr,br,wd,l
n,df,ec,bf,st
Current session parameter. refer to
+FDCC Class 2 command in previous
section parameter settings.
+FKS
Session termination command.
+FLI=
"string"
Local ID string parameter.
+FLO=
n
Flow control options:
n=0
No flow control.
n=1
Set XON/XOFF software flow control.
n=2
Set CTS/RTS hardware flow control.
+FLP=
n
Document for polling command:
n=0
The DTE has no document for polling.
n=1
Indicated document
available for polling.