Brother International Entrepreneur PR-650 Users Manual - English - Page 232
Make sure that each hexagonal screw is, firmly tightened. If any screw remains, loosen, injuries may
View all Brother International Entrepreneur PR-650 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 232 highlights
APPENDIX Lightly press down the ring, and then use the 6 Allen screwdriver (large) to tighten the four hexagonal screws on the inside of the ring. Firmly tighten the screws. ■ Preparing the mounting jig Lower the stopper, and then attach the mounting jig to a stable surface, such as a desk. Use a Phillips screwdriver to loosen the two 1 screws, and then lower the stopper in the direction of the arrow. 1 Ring CAUTION ● Make sure that each hexagonal screw is firmly tightened. If any screw remains loosen, injuries may result. Remove the pad inserted in step 5. 7 1 Loosen the screw so that the stopper can be hooked onto the screw and clamped with it. 2 Loosen until the stopper moves. 3 Stopper Tighten the two screws. 2 • Make sure that the stopper is firmly secured. ■ Installing the needle plate spacer Attach the needle plate spacer to the needle plate. 1 Needle plate spacer Attach the mounting jig to a stable mounting surface, such as a desk. Loosen the thumb screw for the mounting jig 3 to open the mounting bracket so that it is wider than the thickness of the mounting surface. • The mounting bracket can be mounted onto a mounting surface with a thickness from 9 mm (3/8 inch) to 38 mm (1-1/2 inches). 230