Brother International FAX 275 Service Manual - Page 111
Selectors, Maximum, recording, length, start, pseudo, backtone, transmission, through, Attenuator,
UPC - 012502564546
View all Brother International FAX 275 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 111 highlights
Selector No. 1 2 3 4 5 i 8 WSW24 (TAD setting 2) Function Maximum OGM recording time Time length from CML ON to start of pseudo ring backtone transmission Attenuator for playback of ICM/ OGM to the line (Selectable from the range of 015 dB) Setting and Specifications No. 1 2 0 0 : 0 1 : 1 0 : 1 1 : No. 3 4 0 0 : 0 1 : 1 0 : 1 1 : 0: 0 dB 0: 0 dB 0: 0 dB 0: 0 dB 15 sec. 20 sec. 30 sec. 50 sec. 4 sec. 3 sec. 2 sec. 1 sec. 1: 1: 1: 1: 8 dB 4 dB 2 dB 1 dB NOTE: Selectors 1 and 2 are applicable to those models equipped with a built-in TAD. • Selectors 1 and 2: Maximum OGM recording time These selectors set the allowable maximum recording time for an OGM. • Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission These selectors set the length of time from CML-ON up to the start of pseudo ring backtone transmission. In those versions which have an OGM facility, the settings made by these selectors also apply to the length of time from CML-ON up to the start of OGM transmission. • Selectors 5 through 8: Attenuator for playback of ICM/OGM to the line Setting two or more selectors to "1" produces addition of attenuation assigned to each selector. This setting will not be limited by selector 8 of WSW23. V - 37