Brother International FAX 275 Service Manual - Page 113

Application

Page 113 highlights

WSW26 (Function setting 4) Selector No. Function 1 Application of DC wetting pulse 2 Overvoltage limiter at the applying , time of a wetting pulse . 3 Not used. Setting and Specifications 0: OFF 0: ON 1: ON 1: OFF 4 5 No. of CNG cycles to be detected No. 4 5 (when the line is connected via the external telephone except in the 0 0 : 0.5 01 : 1 (A) (B) external TAD mode) 1 0 : 1.5 (C) 11 : 2 (D) No. of CNG cycles to be detected No. 6 7 6 (when the line is connected via the 0 0 : 0.5 (A) external telephone in the external 01 : 1 (B) 7 TAD mode or via the facsimile 1 0 : 1.5 (C) equipment in F/T mode) 11 : 2 (D) 8 FAX reception after the time-out of pseudo ring backtones in F/T mode 0: Yes 1: No NOTE: Selectors 1 and 2 are not applicable to the German versions. NOTE: Selectors 6 and 7 are not applicable to those models equipped with a built-in TAD. • Selectors 1 and 2: Application of DC wetting pulse and overvoltage limiter These selectors take effect only when the UK version of the facsimile equipment is set up for the British Telecom's caller ID service or its equivalent. Selector 2 takes effect only when selector 1 is set to "1." • Selectors 4 and 5: No. of CNG cycles to be detected The equipment interprets a CNG as an effective signal if it detects a CNG signal by the number of cycles specified by these selectors when the line is connected via the external telephone except in the external TAD mode. • Selectors 6 and 7: No. of CNG cycles to be detected The equipment interprets a CNG as an effective signal if it detects a CNG signal by the number of cycles specified by these selectors when the line is connected via the external telephone in the external TAD mode or via the facsimile equipment in F/T mode. • Selector 8: FAX reception after the time-out of pseudo ring backtones in F/T mode If this selector is set to "0," the equipment starts receiving FAX messages when it receives a CNG signal within 10-second no-tone period provided after the time-out of pseudo ring backtones. If no CNG is received within the period, the equipment disconnects the line. If this selector is set to "1," the equipment disconnects the line after issuing pseudo ring backtones. V - 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267

WSW26
(Function
setting
4)
Selector
No.
Function
Setting
and
Specifications
1
Application
of
DC
wetting
pulse
0:
OFF
1:
ON
2
Overvoltage
limiter
at
the
applying
time
of
a
wetting
pulse
0:
ON
1:
OFF
3
,
.
Not
used.
4
5
No.
of
CNG
cycles
to
be
detected
(when
the
line
is
connected
via
the
external
telephone
except
in
the
external
TAD
mode)
No.
4
0
0
1
1
5
0
:
1
:
0
:
1
:
0.5
1
1.5
2
(A)
(B)
(C)
(D)
6
7
No.
of
CNG
cycles
to
be
detected
(when
the
line
is
connected
via
the
external
telephone
in
the
external
TAD
mode
or
via
the
facsimile
equipment
in
F/T
mode)
No.
6
0
0
1
1
7
0
:
1
:
0
:
1
:
0.5
1
1.5
2
(A)
(B)
(C)
(D)
8
FAX
reception
after
the
time-out
of
pseudo
ring
backtones
in
F/T
mode
0:
Yes
1:
No
NOTE:
Selectors
1
and
2
are
not
applicable
to
the
German
versions.
NOTE:
Selectors
6
and
7
are
not
applicable
to
those
models
equipped
with
a
built-in
TAD.
Selectors
1
and
2:
Application
of
DC
wetting
pulse
and
overvoltage
limiter
These
selectors
take
effect
only
when
the
UK
version
of
the
facsimile
equipment
is
set
up
for
the
British
Telecom's caller
ID
service
or
its
equivalent.
Selector
2
takes
effect
only
when
selector
1
is
set
to
"1."
Selectors
4
and
5:
No.
of
CNG
cycles
to
be
detected
The
equipment
interprets
a
CNG
as
an
effective
signal
if
it
detects
a
CNG
signal
by
the
number
of
cycles
specified
by
these
selectors
when
the
line
is
connected
via
the
external
telephone
except
in
the
external
TAD
mode.
Selectors
6
and
7:
No.
of
CNG
cycles
to
be
detected
The
equipment
interprets
a
CNG
as
an
effective
signal
if
it
detects
a
CNG
signal
by
the
number
of
cycles
specified
by
these
selectors
when
the
line
is
connected
via
the
external
telephone
in
the
external
TAD
mode
or
via
the
facsimile
equipment
in
F/T
mode.
Selector
8:
FAX
reception
after
the
time-out
of
pseudo
ring
backtones
in
F/T
mode
If
this
selector
is
set
to
"0,"
the
equipment
starts
receiving
FAX
messages
when
it
receives
a
CNG
signal
within
10
-second
no
-tone
period
provided
after
the
time-out
of
pseudo
ring
backtones.
If
no
CNG
is
received
within
the
period,
the
equipment
disconnects
the
line.
If
this
selector
is
set
to
"1,"
the
equipment
disconnects
the
line
after
issuing
pseudo
ring
backtones.
V
-