Brother International HL-6180DW User's Guide - English - Page 117
Drum Stop, Replacing the drum unit, following steps - reset drum
View all Brother International HL-6180DW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 117 highlights
Routine Maintenance Drum Stop 5 Drum Stop We cannot guarantee the print quality. Please replace the drum unit with a new one. We recommend a genuine Brother drum unit be installed at this time. After replacement, reset the drum counter by following the instructions included with the new drum unit. Replacing the drum unit 5 Important • While removing the drum unit, handle it carefully because it may contain toner. If toner scatters on your hands or clothes, immediately wipe or wash it off with cold water. 5 • Every time you replace the drum unit, clean the inside of the machine. (See Cleaning and Checking the machine uu page 116.) When you replace the drum unit with a new one, you need to reset the drum counter by completing the following steps: a Make sure that the machine is turned on. Leave the machine for at least 10 minutes to cool down. b Press the front cover release button and then open the front cover. c Take out the drum unit and toner cartridge assembly. 111