Cisco N5K-C5010P-BF Troubleshooting Guide - Page 115

Cisco Nexus 5000 Series Troubleshooting Guide, OL-25300-01,

Page 115 highlights

Chapter 5 Troubleshooting SAN Switching Issues VSANs Send document comments to [email protected]. OL-25300-01 version 5.0(1a) interface fc1/1 switchport rate-mode dedicated switchport mode E switchport trunk allowed vsan 100 no shutdown switch(config-if)# interface fc 2/3 switch(config-if)# switchport trunk allowed vsan add all switch(config-if)# switchport trunk allowed vsan add 100 switch(config-if)# show run interface fc 2/3 !Command: show running-config interface fc2/3 !Time: Wed Aug 4 16:07:25 2010 version 4.2(1)N1(1) interface fc2/3 switchport mode E switchport trunk allowed vsan 1 switchport trunk allowed vsan add 100 no shutdown switch(config-if)# switchport trunk allowed vsan add 1 switch(config-if)# show run interface fc 1/1 !Command: show running-config interface fc1/1 !Time: Wed Aug 4 16:20:54 2010 version 5.0(1a) interface fc1/1 switchport rate-mode dedicated switchport mode E switchport trunk allowed vsan 1 switchport trunk allowed vsan add 100 no shutdown fc2/3 is trunking Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN) Port WWN is 20:43:00:0d:ec:da:6e:00 Peer port WWN is 20:01:00:0d:ec:24:5b:c0 Admin port mode is E, trunk mode is on snmp link state traps are enabled Port mode is TE Port vsan is 1 Speed is 4 Gbps Transmit B2B Credit is 250 Receive B2B Credit is 16 Receive data field Size is 2112 Beacon is turned off Trunk vsans (admin allowed and active) (1,100) Trunk vsans (up) (1,100) Trunk vsans (isolated) () Trunk vsans (initializing) () switch(config-if)# show interface brief Interface Vsan Admin Admin Status SFP Oper Oper Port Mode Trunk Mode Speed Channel Cisco Nexus 5000 Series Troubleshooting Guide 5-43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162

Send document comments to [email protected].
5-43
Cisco Nexus 5000 Series Troubleshooting Guide
OL-25300-01
Chapter 5
Troubleshooting SAN Switching Issues
VSANs
version 5.0(1a)
interface fc1/1
switchport rate-mode dedicated
switchport mode E
switchport trunk allowed vsan 100
no shutdown
switch(config-if)# interface fc 2/3
switch(config-if)# switchport trunk allowed vsan
add
all
switch(config-if)# switchport trunk allowed vsan add 100
switch(config-if)# show run interface fc 2/3
!Command: show running-config interface fc2/3
!Time: Wed Aug
4 16:07:25 2010
version 4.2(1)N1(1)
interface fc2/3
switchport mode E
switchport trunk allowed vsan 1
switchport trunk allowed vsan add 100
no shutdown
switch(config-if)# switchport trunk allowed vsan add 1
switch(config-if)# show run interface fc 1/1
!Command: show running-config interface fc1/1
!Time: Wed Aug
4 16:20:54 2010
version 5.0(1a)
interface fc1/1
switchport rate-mode dedicated
switchport mode E
switchport trunk allowed vsan 1
switchport trunk allowed vsan add 100
no shutdown
fc2/3 is trunking
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
Port WWN is 20:43:00:0d:ec:da:6e:00
Peer port WWN is 20:01:00:0d:ec:24:5b:c0
Admin port mode is E, trunk mode is on
snmp link state traps are enabled
Port mode is TE
Port vsan is 1
Speed is 4 Gbps
Transmit B2B Credit is 250
Receive B2B Credit is 16
Receive data field Size is 2112
Beacon is turned off
Trunk vsans (admin allowed and active) (1,100)
Trunk vsans (up)
(1,100)
Trunk vsans (isolated)
()
Trunk vsans (initializing)
()
switch(config-if)# show interface brief
-------------------------------------------------------------------------------
Interface
Vsan
Admin
Admin
Status
SFP
Oper
Oper
Port
Mode
Trunk
Mode
Speed
Channel