Cisco N5K-C5010P-BF Troubleshooting Guide - Page 95
Fibre channel port is suspended due to too many invalid FLOGIs, fspf config vsan, show logging
UPC - 882658212208
View all Cisco N5K-C5010P-BF manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 95 highlights
Chapter 5 Troubleshooting SAN Switching Issues FC Services Send document comments to [email protected]. Step 5 FSPF routing for VSAN 200 FSPF routing administration status is enabled FSPF routing operational status is UP It is an intra-domain router Autonomous region is 2 SPF hold time is 0 msec MinLsArrival = 1000 msec , MinLsInterval = 2000 msec Local Domain is 0x22(34) Number of LSRs = 1, Total Checksum = 0x00000c10 switch# show fspf vsan 200 FSPF routing for VSAN 200 FSPF routing administration status is enabled FSPF routing operational status is UP It is an intra-domain router Autonomous region is 0 SPF hold time is 0 msec MinLsArrival = 1000 msec , MinLsInterval = 2000 msec Local Domain is 0x18(24) Number of LSRs = 2, Total Checksum = 0x00014f9f Use the fspf config vsan command to enter the FSPF configuration mode and use the region command to change the region. The region must match on all switches in the VSAN. Example: switch(config)# fspf config vsan 200 switch(config-(fspf-config))# region 0 Fibre channel port is suspended due to too many invalid FLOGIs A Fibre Channel node that is connected to an NPV feature-enabled Cisco Nexus 5000 switch or a Cisco Nexus 5000 switch that is running in fabric mode cannot log into the SAN fabric due to a FLOGI rejection. The following example shows possible log messages from the show logging command log. Example: %FLOGI-1-MSG_FLOGI_REJECT_FCID_ERROR: %$VSAN %$ [VSAN , Interface fcslot/port/: mode[F]] FLOGI rejected - FCID allocation failed. PORT-5-IF_DOWN_TOO_MANY_INVALID_FLOGIS: %$VSAN %$ Interface fc slot/port is down (Suspended due to too many invalid flogis The status of the interface shows invalidFlogis. show interface fc slot/port brief fc slot/port F -- invalidFlogis Possible Cause The FC ID persistency table for that VSAN might be full. If the Nexus 5000 Series switch is configured as an NPV edge switch, the FC ID persistency table of the NPV core switch might be full. FC IDs: When an N port logs into a Cisco Nexus 5000 Series switch, it is assigned an FC ID. By default, the persistent FC ID feature is enabled. If this feature is disabled, the following situations can occur: OL-25300-01 Cisco Nexus 5000 Series Troubleshooting Guide 5-23