Compaq 315eu Maintenance and Service Guide - Compaq 100eu Small Form Factor, 1 - Page 210
All-in One models
View all Compaq 315eu manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 210 highlights
All-in One models Table C-3 Specifications Desktop Dimensions Height Width Depth 19.06 in 12.95 in 2.25 in 48.4 cm 32.9 cm 5.7 cm Approximate Weight 22.4 lb 10.2 kg Temperature Range Operating Nonoperating 50° to 95°F -22° to 140°F 10° to 35°C -30° to 60°C Relative Humidity Operating Nonoperating (38.7°C max wet bulb) 10-90% 5-95% 10-90% 5-95% Maximum Altitude (unpressurized) Operating Nonoperating 10,000 ft 30,000 ft 3048 m 9144 m NOTE: Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed. Power Supply 115V 230V Operating Voltage Range 90-140 VAC 180-264 VAC Rated Voltage Range 100-127 VAC 200-240 VAC Rated Line Frequency 50-60 Hz 50-60 Hz Operating Line Frequency 47-63 Hz 47-63 Hz Power Output 65 W 65 W 1 This system utilizes a passive power factor corrected power supply. The power factor correction is present in the 230V operating mode only. This allows the system to pass the CE mark requirements for use in the countries of the European Union. This supply requires the use of an input voltage range select switch. 200 Appendix C Specifications