Chapter Removal and Replacement Procedures (RRPs) 4 In this chapter •RRP: Power supply 25 •RRP: Fan assembly 28 Introduction NOTE Read the "Installation and safety considerations" before servicing. The field replaceable units (FRUs) in the Powerconnect B-8000 can be removed and replaced without special tools. The PowerConnect B-8000 can continue operating during many of the FRU replacements if the conditions specified in the procedure are followed. The following sections contain FRU removal and replacement procedures (RRPs). RRP: Power supply The PowerConnect B-8000 has two power supplies, as displayed in Figure 6. Fabric OS identifies the power supplies from right to left on the non-port side as power supply 1 and power supply 2. (The actual appearance of the PowerConnect B-8000 may differ from this illustration but the locations are correct.) FIGURE 6 Switch power supplies on the non-port side 2 1 1 Power supply 1 2 Power supply 2 CAUTION Disassembling any part of the power supply voids the part warranty and regulatory certifications. There are no user-serviceable parts inside the power supply. The cooling system relies on pressurized air, do not leave either of the power supply slots empty longer than two minutes when PowerConnect B-8000 Hardware Reference Manual 25 53-1001788-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

PowerConnect B-8000 Hardware Reference Manual
25
53-1001788-01
Chapter
4
Removal and Replacement Procedures (RRPs)
In this chapter
RRP: Power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
RRP: Fan assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
28
Introduction
NOTE
Read the
“Installation and safety considerations”
before servicing.
The field replaceable units (FRUs) in the Powerconnect B-8000 can be removed and replaced
without special tools. The PowerConnect B-8000 can continue operating during many of the FRU
replacements if the conditions specified in the procedure are followed.
The following sections contain FRU removal and replacement procedures (RRPs).
RRP: Power supply
The PowerConnect B-8000 has two power supplies, as displayed in
Figure 6
. Fabric OS identifies
the power supplies from right to left on the non-port side as power supply 1 and power supply 2.
(The actual appearance of the PowerConnect B-8000 may differ from this illustration but the
locations are correct.)
FIGURE 6
Switch power supplies on the non-port side
CAUTION
Disassembling any part of the power supply voids the part warranty and regulatory certifications.
There are no user-serviceable parts inside the power supply. The cooling system relies on
pressurized air, do not leave either of the power supply slots empty longer than two minutes when
1
Power supply 1
2
Power supply 2
1
2