Dell PowerEdge M420 8/4 Gbps FC SAN Module Administrator's Guide - Page 18

Port mapping

Page 18 highlights

2 Port mapping Port mapping The FC SAN Module uses port-mapped pre-provisioned routes to direct traffic from the blade server (HBAs) to the fabric. When you first turn on the module, by default, the internal ports (F_Ports) are mapped to a set of predefined external ports (N_Ports). For the default port mapping, see Table 3 on page 5. See t "Remapping ports" on page 5 if you want to change the default mapping. Figure 2 shows a mapping with eight internal ports (F_Ports) evenly mapped to four external ports (N_Ports). External ports connect to the same fabric through different Edge switches. Blade Servers Blade_1 Blade_2 Blade_3 FC SAN Module F_1 N_1 F_2 N_2 F_3 Edge Switch (Switch_A) F_A1 NPIV enabled F_A2 NPIV enabled Fabric Blade_4 F_4 Blade_5 F_5 Blade_6 F_6 N_3 N_4 Edge Switch (Switch_B) F_B1 NPIV enabled F_B2 NPIV enabled Blade_7 F_7 Blade_8 F_8 FIGURE 2 Example NPIV port mapping Table 2 provides a description of the port mapping in Figure 2. TABLE 2 Description of port mapping in preceding figure NPIV Switch Fabric F_Port N_Port Edge switch F_Port F_1, F_2 N_1 F_3, F_4 N_2 F_5, F_6 N_3 F_7, F_8 N_4 Switch_A Switch_A Switch_B Switch_B F_A1 F_A2 F_B1 F_B2 4 Dell 8/4Gbps FC SAN Module Administrator's Guide 53-1001345-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

4
Dell 8/4Gbps FC SAN Module Administrator’s Guide
53-1001345-01
Port mapping
2
Port mapping
The FC SAN Module uses port-mapped pre-provisioned routes to direct traffic from the blade server
(HBAs) to the fabric. When you first turn on the module, by default, the internal ports (F_Ports) are
mapped to a set of predefined external ports (N_Ports). For the default port mapping, see
Table 3
on page 5. See t
“Remapping ports”
on page 5 if you want to change the default mapping.
Figure 2
shows a mapping with eight internal ports (F_Ports) evenly mapped to four external ports (N_Ports).
External ports connect to the same fabric through different Edge switches.
FIGURE 2
Example NPIV port mapping
Table 2
provides a description of the port mapping in
Figure 2
.
TABLE 2
Description of port mapping in preceding figure
NPIV Switch
Fabric
F_Port
N_Port
Edge switch
F_Port
F_1, F_2
N_1
Switch_A
F_A1
F_3, F_4
N_2
Switch_A
F_A2
F_5, F_6
N_3
Switch_B
F_B1
F_7, F_8
N_4
Switch_B
F_B2
N_2
F_A2
Blade Servers
FC SAN Module
Edge Switch
Fabric
(Switch_A)
enabled
NPIV
F_4
F_3
F_2
F_1
N_1
F_A1
enabled
NPIV
N_3
F_B1
enabled
NPIV
Blade_1
Blade_2
Blade_3
Blade_4
F_5
Blade_5
F_6
Blade_6
F_7
Blade_7
F_8
Blade_8
Edge Switch
(Switch_B)
N_4
F_B2
enabled
NPIV