Dell PowerEdge M420 8/4 Gbps FC SAN Module Administrator's Guide - Page 68

Understanding Virtual Fabric restrictions, Understanding, Admin Domain restrictions, FC Fastwrite

Page 68 highlights

B portCfgShow Notes Operands Examples FC Fastwrite Rate Limit Credit Recovery Port Auto Disable F_Port Buffers Displays ON when FC Fastwrite is enabled on the port or (..) or OFF when disabled. Fastwrite is disabled by default. This value is set by the portCfg fastwrite command. Displays ON when ingress rate limit is set on the port or (..) or OFF when the ingress rate limiting feature is disabled. This value is set by the portCfgQos --setratelimit command. The default value is OFF. Displays ON when Credit Recovery is enabled on the port. Displays (..) or OFF when the feature is disabled. This value is set by the portCfgCreditRecovery command. The credit recovery feature is enabled by default, but only ports configured as long distance ports can utilize this feature. Displays On when the Auto Disable feature is enabled on a port. Displays (..) or OFF when the feature is disabled. This feature causes ports to become disabled when they encounter an event that would cause them to reinitialize. This feature is enabled by the portCfgAutoDisable command. The feature is disabled by default. Displays the number of configured internal port (F_Port) buffers. Displays (..) or OFF if no buffers are configured. The buffer value is set by the portCfgfPortbuffers command. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to "Understanding Virtual Fabric restrictions" on page 32 snf "Understanding Admin Domain restrictions" on page 33 for details. This command supports the following operands: slot For bladed systems only, specifies the slot number of the port to be configured, followed by a slash (/). port Specifies the number of the port to be displayed, relative to its slot for bladed systems. Use portCfgshow with one of the following options and optional arguments to display specific FCIP-related parameters configured for a GbE port: To display the configuration settings for a single port on a switch with NPIV mode enabled: switch:admin> portcfgshow 8 Area Number: Speed Level: Fill Word: Trunk Port Locked N_Port Persistent Disable NPIV capability QOS Port Port Auto Disable: Rate Limit F_Port Buffers 8 AUTO(HW) 0(Idle-Idle) ON OFF OFF ON AE OFF OFF OFF To display the configuration settings for all ports on a switch with NPIV Mode enabled: Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN Fill Word 0000 0000 0000 0000 54 Dell 8/4Gbps FC SAN Module Administrator's Guide 53-1001345-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

54
Dell 8/4Gbps FC SAN Module Administrator’s Guide
53-1001345-01
portCfgShow
B
FC Fastwrite
Displays ON when FC Fastwrite is enabled on the port or (..) or OFF when
disabled. Fastwrite is disabled by default. This value is set by the
portCfg
fastwrite
command.
Rate Limit
Displays ON when ingress rate limit is set on the port or (..) or OFF when the
ingress rate limiting feature is disabled. This value is set by the
portCfgQos
--
setratelimit
command. The default value is OFF.
Credit Recovery
Displays ON when Credit Recovery is enabled on the port. Displays (..) or OFF
when the feature is disabled. This value is set by the
portCfgCreditRecovery
command. The credit recovery feature is enabled by default, but only ports
configured as long distance ports can utilize this feature.
Port Auto Disable
Displays On when the Auto Disable feature is enabled on a port. Displays (..)
or OFF when the feature is disabled. This feature causes ports to become
disabled when they encounter an event that would cause them to reinitialize.
This feature is enabled by the
portCfgAutoDisable
command. The feature is
disabled by default.
F_Port Buffers
Displays the number of configured internal port (F_Port) buffers. Displays (..)
or OFF if no buffers are configured. The buffer value is set by the
portCfgfPortbuffers
command.
Notes
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to
“Understanding Virtual Fabric restrictions”
on page 32 snf
“Understanding
Admin Domain restrictions”
on page 33 for details.
Operands
This command supports the following operands:
slot
For bladed systems only, specifies the slot number of the port to be
configured, followed by a slash (/).
port
Specifies the number of the port to be displayed, relative to its slot for bladed
systems.
Use
portCfgshow
with one of the following options and optional arguments to display specific
FCIP-related parameters configured for a GbE port:
Examples
To display the configuration settings for a single port on a switch with NPIV mode enabled:
switch:admin>
portcfgshow 8
Area Number:
8
Speed Level:
AUTO(HW)
Fill Word:
0(Idle-Idle)
Trunk Port
ON
Locked N_Port
OFF
Persistent Disable
OFF
NPIV capability
ON
QOS Port
AE
Port Auto Disable:
OFF
Rate Limit
OFF
F_Port Buffers
OFF
To display the configuration settings for all ports on a switch with NPIV Mode enabled:
Ports of Slot 0
0
1
2
3
4
5
6
7
8
9 10 11
12 13 14 15
-----------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+--
Speed
AN AN AN AN
AN AN AN AN
AN AN AN AN
AN AN AN AN
Fill Word
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0