Dell PowerEdge M420 8/4 Gbps FC SAN Module Administrator's Guide - Page 73

The status of FC Fastwrite ON or OFF., Gbps, N4 Gbps, N8 Gbps or AN.

Page 73 highlights

portShow B Port part of other AD Yes or No. portSpeed The port's fixed speed (1, 2, 4, or 8 Gbps) or negotiated speed (N1 Gbps, N2 Gbps, N4 Gbps, N8 Gbps or AN). LE domain The LE domain ID. FC Fastwrite The status of FC Fastwrite (ON or OFF). If the port is configured as an EX_Port, the following additional port information is displayed: EX_Port Mode The port is configured as an EX_Port. Fabric ID The fabric ID assigned to this EX_Port; this is the fabric ID of the edge fabric attached to this EX_Port. Front Phantom Information on the front phantom domain presented by this EX_Port. Includes the preferred (if not active) or actual (if active) domain ID for the front domain and the WWN of the front domain. Pr Switch Info Information on the principal switch of the edge fabric attached to this EX_Port. Includes the domain ID and WWN of the principal switch. BB XLate Information on the xlate (translate) phantom domain presented at this port. Includes the preferred (if not active) or actual (if active) domain ID for the xlate phantom domain and the WWN of the xlate phantom domain. The xlate phantom domain connected at this port is in the same fabric as the router and represents the edge fabric connected to the EX_Port. Authentication Type Displays NONE or DH-CHAP. DH-CHAP is the only authentication type supported on EX_Ports. DH Group Displays DH group [0-4] if DH-CHAP authentication is used. Otherwise displays N/A. Hash Algorithm Displays hash type (MD5 or SHA-1) if DH-CHAP authentication is used. Otherwise, displays N/A. Edge fabric's primary WWN If the EX_Port is connected to an edge switch with FCS policy enforcement, the WWN of the primary FCS is displayed when the edge fabric is secure and the primary FCS is online. Otherwise, displays "No Primary". Edge fabric's version stamp If the EX_PORT is connected to an edge switch with FCS policy enforcement, the version of the security database is displayed. Otherwise displays N/A. If the port is configured as a VE_Port, the command shows FC and Physical layer attributes of the underlying port, as well as status information regarding the underlying FCIP link for those logical FC ports that are instantiated over a physical 1/10GbE port. Refer to the example section for an illustration. Following the general information, the command displays three columns of counters. The first column shows interrupt statistics: Interrupts Total number of interrupts. Unknown Interrupts that are not counted elsewhere. Dell 8/4Gbps FC SAN Module Administrator's Guide 59 53-1001345-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

Dell 8/4Gbps FC SAN Module Administrator’s Guide
59
53-1001345-01
portShow
B
Port part of other AD
Yes or No.
portSpeed
The port's fixed speed (1, 2, 4, or 8 Gbps) or negotiated speed (N1 Gbps, N2
Gbps, N4 Gbps, N8 Gbps or AN).
LE domain
The LE domain ID.
FC Fastwrite
The status of FC Fastwrite (ON or OFF).
If the port is configured as an EX_Port, the following additional port information is displayed:
EX_Port Mode
The port is configured as an EX_Port.
Fabric ID
The fabric ID assigned to this EX_Port; this is the fabric ID of the edge fabric
attached to this EX_Port.
Front Phantom
Information on the front phantom domain presented by this EX_Port. Includes
the preferred (if not active) or actual (if active) domain ID for the front domain
and the WWN of the front domain.
Pr Switch Info
Information on the principal switch of the edge fabric attached to this
EX_Port. Includes the domain ID and WWN of the principal switch.
BB XLate
Information on the xlate (translate) phantom domain presented at this port.
Includes the preferred (if not active) or actual (if active) domain ID for the
xlate phantom domain and the WWN of the xlate phantom domain. The xlate
phantom domain connected at this port is in the same fabric as the router
and represents the edge fabric connected to the EX_Port.
Authentication Type
Displays NONE or DH-CHAP. DH-CHAP is the only authentication type
supported on EX_Ports.
DH Group
Displays DH group [0-4] if DH-CHAP authentication is used. Otherwise
displays N/A.
Hash Algorithm
Displays hash type (MD5 or SHA-1) if DH-CHAP authentication is used.
Otherwise, displays N/A.
Edge fabric’s primary WWN
If the EX_Port is connected to an edge switch with FCS policy enforcement,
the WWN of the primary FCS is displayed when the edge fabric is secure and
the primary FCS is online. Otherwise, displays “No Primary”.
Edge fabric’s version stamp
If the EX_PORT is connected to an edge switch with FCS policy enforcement,
the version of the security database is displayed. Otherwise displays N/A.
If the port is configured as a VE_Port, the command shows FC and Physical layer attributes of the
underlying port, as well as status information regarding the underlying FCIP link for those logical FC
ports that are instantiated over a physical 1/10GbE port. Refer to the example section for an
illustration.
Following the general information, the command displays three columns of counters. The first
column shows interrupt statistics:
Interrupts
Total number of interrupts.
Unknown
Interrupts that are not counted elsewhere.