Dell PowerEdge M420 8/4 Gbps FC SAN Module Administrator's Guide - Page 40

Verifying the switch mode, Before connecting the FC SAN Module to Brocade switches

Page 40 highlights

4 Fabric and Edge switch configuration • If DCC security is being used on Edge switches that directly connect to the FC SAN Module, make sure to include the module WWN or the port WWN of the external ports (N_Ports). Also include the HBA WWNs that will be connected to internal ports (F_Ports) to the ACL list in the ACL policy. It is recommended to use FC SAN Module ADS policy instead of the DCC policy on the Edge switch. • Allow inband queries for forwarded fabric management requests from the hosts. Add the FC SAN Module WWN to the access list if inband queries are restricted. Before connecting the FC SAN Module to Brocade switches, disable the Brocade Fabric OS Management Server Platform Service to get accurate statistical and configuration fabric data, Verifying the switch mode 1. Connect to the switch and log in using an account assigned to the admin role. 2. Enter the switchShow command to display the current switch configuration. The following example shows a switch in the Fabric OS Native mode where switchMode displays as Native. switch:admin> switchshow switchName: switch switchType: 43.2 switchState: Online switchMode: Native switchRole: Principal switchDomain: 1 switchId: fffc01 switchWwn: 10:00:00:05:1e:03:4b:e7 zoning: OFF switchBeacon: OFF Area Port Media Speed State Proto 0 0 -- N4 No_Module 1 1 cu N4 Online F-Port 50:06:0b:00:00:3c:b7:32 2 2 cu N4 Online F-Port 10:00:00:00:c9:35:43:f5 3 3 cu AN No_Sync 4 4 cu AN No_Sync Disabled (Persistent) 5 5 cu N4 Online F-Port 50:06:0b:00:00:3c:b4:3e 6 6 cu N4 Online F-Port 10:00:00:00:c9:35:43:f3 7 7 cu AN No_Sync Disabled (Persistent) 8 8 cu AN No_Sync 9 9 cu AN No_Sync Disabled (Persistent) 10 10 cu AN No_Sync Disabled (Persistent) 11 11 cu AN No_Sync Disabled (Persistent) 12 12 cu AN No_Sync Disabled (Persistent) 13 13 cu AN No_Sync Disabled (Persistent) 14 14 cu AN No_Sync Disabled (Persistent) 15 15 cu AN No_Sync Disabled (Persistent) 16 16 cu AN No_Sync Disabled (Persistent) 17 17 -- N4 No_Module 18 18 -- N4 No_Module 19 19 -- N4 No_Module 20 20 -- N4 No_Module 21 21 id N4 Online E-Port segmented,(zone conflict)(Trunk master) 22 22 id N4 Online E-Port (Trunk port, master is Port 21 ) 26 Dell 8/4Gbps FC SAN Module Administrator's Guide 53-1001345-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

26
Dell 8/4Gbps FC SAN Module Administrator’s Guide
53-1001345-01
Fabric and Edge switch configuration
4
If DCC security is being used on Edge switches that directly connect to the FC SAN Module,
make sure to include the module WWN or the port WWN of the external ports (N_Ports). Also
include the HBA WWNs that will be connected to internal ports (F_Ports) to the ACL list in the
ACL policy. It is recommended to use FC SAN Module ADS policy instead of the DCC policy on
the Edge switch.
Allow inband queries for forwarded fabric management requests from the hosts. Add the FC
SAN Module WWN to the access list if inband queries are restricted.
Before connecting the FC SAN Module to Brocade switches, disable the Brocade Fabric OS
Management Server Platform Service to get accurate statistical and configuration fabric data,
Verifying the switch mode
1.
Connect to the switch and log in using an account assigned to the admin role.
2.
Enter the
switchShow
command to display the current switch configuration.
The following example shows a switch in the Fabric OS Native mode where
switchMode
displays as Native.
switch:admin>
switchshow
switchName:
switch
switchType:
43.2
switchState:
Online
switchMode:
Native
switchRole:
Principal
switchDomain:
1
switchId:
fffc01
switchWwn:
10:00:00:05:1e:03:4b:e7
zoning:
OFF
switchBeacon:
OFF
Area Port Media Speed State
Proto
=====================================
0
0
--
N4
No_Module
1
1
cu
N4
Online
F-Port
50:06:0b:00:00:3c:b7:32
2
2
cu
N4
Online
F-Port
10:00:00:00:c9:35:43:f5
3
3
cu
AN
No_Sync
4
4
cu
AN
No_Sync
Disabled (Persistent)
5
5
cu
N4
Online
F-Port
50:06:0b:00:00:3c:b4:3e
6
6
cu
N4
Online
F-Port
10:00:00:00:c9:35:43:f3
7
7
cu
AN
No_Sync
Disabled (Persistent)
8
8
cu
AN
No_Sync
9
9
cu
AN
No_Sync
Disabled (Persistent)
10
10
cu
AN
No_Sync
Disabled (Persistent)
11
11
cu
AN
No_Sync
Disabled (Persistent)
12
12
cu
AN
No_Sync
Disabled (Persistent)
13
13
cu
AN
No_Sync
Disabled (Persistent)
14
14
cu
AN
No_Sync
Disabled (Persistent)
15
15
cu
AN
No_Sync
Disabled (Persistent)
16
16
cu
AN
No_Sync
Disabled (Persistent)
17
17
--
N4
No_Module
18
18
--
N4
No_Module
19
19
--
N4
No_Module
20
20
--
N4
No_Module
21
21
id
N4
Online
E-Port
segmented,(zone conflict)(Trunk
master)
22
22
id
N4
Online
E-Port