Dell PowerEdge M420 8/4 Gbps FC SAN Module Administrator's Guide - Page 37
Enabling and disabling Failback on an external port (N_Port), ag --failbackshow 13
View all Dell PowerEdge M420 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Failback 3 Example 3 Blade Servers Blade_1 Blade_2 Blade_3 FC SAN Module F_1 N_1 F_2 N_2 F_3 Blade_4 F_4 N_3 Blade_5 F_5 N_4 Blade_6 F_6 Edge Switch (Switch_A) F_A1 NPIV enabled F_A2 NPIV enabled Edge Switch (Switch_B) F_B1 NPIV enabled F_B2 NPIV enabled Fabric Blade_7 F_7 Blade_8 F_8 FIGURE 6 Failback behavior Legend Physical connection Mapped online Failover route online Original mapped route (offline) Enabling and disabling Failback on an external port (N_Port) Use the following steps to enable or disable Failback on external ports. 1. Connect to the FC SAN Module and log in using an account assigned to the admin role. 2. Enter the ag --failbackshow n_portnumber command to display the failover setting. switch:admin> ag --failbackshow 13 Failback on N_Port 13 is not supported 3. Use the following commands to enable or disable Failback: • Enter the ag --failbackenable n_portnumber command to enable failback. switch:admin> ag --failbackenable 13 Failback policy is enabled for port 13 • Enter the ag --failbackdisable n_portnumber command to disable failback. switch:admin> ag --failbackdisable 13 Failback policy is disabled for port 13 Dell 8/4Gbps FC SAN Module Administrator's Guide 23 53-1001345-01