Dell PowerEdge M420 8/4 Gbps FC SAN Module Administrator's Guide - Page 70

portCfgSpeed, of the following

Page 70 highlights

B portCfgSpeed NPIV capability ON QOS E_Port AE Port Auto Disable: OFF Rate Limit OFF EX Port ON Mirror Port OFF Credit Recovery ON F_Port Buffers OFF portCfgSpeed Synopsis Description Notes Operands Configures the speed for a single port. portcfgspeed [slotnumber/]portnumber, speed Use this command to set the speed on a specified port. This command disables and then re-enables the port, and the port comes online with the new speed setting. The configuration is saved in nonvolatile memory and is persistent across switch reboots or power cycles. Use the portShow command to display actual port speed levels. Use the portCfgShow command to display user-specified speed settings. This configuration cannot be set on VE/VEX_Ports. For a virtual FC port, the speed is always 10 GbE and port speed auto-negotiation is not possible. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to "Understanding Virtual Fabric restrictions" on page 32 and "Understanding Admin Domain restrictions" on page 33 for details. This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port to be configured, followed by a slash (/). portnumber Specifies the port to be configured, relative to its slot for bladed systems. Use switchShow for a listing of valid ports. speed_level Specifies the speed of a port. This operand is required. Valid values are one of the following: 0 Auto-sensing mode (hardware). The port automatically configures for maximum speed. ax Auto-sensing mode (hardware). The port automatically configures for maximum speed with enhanced retries. s Auto-sensing mode (software). The port automatically configures for maximum speed with enhanced retries. 1 The port is set at a fixed speed of 1 Gbps. 2 The port is set at a fixed speed of 2 Gbps. 4 The port is set at a fixed speed of 4 Gbps. 8 The port is set at a fixed speed of 8 Gbps. 56 Dell 8/4Gbps FC SAN Module Administrator's Guide 53-1001345-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

56
Dell 8/4Gbps FC SAN Module Administrator’s Guide
53-1001345-01
portCfgSpeed
B
NPIV capability
ON
QOS E_Port
AE
Port Auto Disable:
OFF
Rate Limit
OFF
EX Port
ON
Mirror Port
OFF
Credit Recovery
ON
F_Port Buffers
OFF
portCfgSpeed
Configures the speed for a single port.
Synopsis
portcfgspeed
[
slotnumber
/
]
portnumber
,
speed
Description
Use this command to set the speed on a specified port. This command disables and then
re-enables the port, and the port comes online with the new speed setting. The configuration is
saved in nonvolatile memory and is persistent across switch reboots or power cycles.
Use the
portShow
command to display actual port speed levels. Use the
portCfgShow
command to
display user-specified speed settings.
Notes
This configuration cannot be set on VE/VEX_Ports. For a virtual FC port, the speed is always 10 GbE
and port speed auto-negotiation is not possible.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to
“Understanding Virtual Fabric restrictions”
on page 32 and
“Understanding
Admin Domain restrictions”
on page 33 for details.
Operands
This command has the following operands:
slotnumber
For bladed systems only, specifies the slot number of the port to be
configured, followed by a slash (/).
portnumber
Specifies the port to be configured, relative to its slot for bladed systems. Use
switchShow
for a listing of valid ports.
speed_level
Specifies the speed of a port. This operand is required. Valid values are one
of the following:
0
Auto-sensing mode (hardware). The port automatically configures for
maximum speed.
ax
Auto-sensing mode (hardware). The port automatically configures for
maximum speed with enhanced retries.
s
Auto-sensing mode (software). The port automatically configures for
maximum speed with enhanced retries.
1
The port is set at a fixed speed of 1 Gbps.
2
The port is set at a fixed speed of 2 Gbps.
4
The port is set at a fixed speed of 4 Gbps.
8
The port is set at a fixed speed of 8 Gbps.