Dell PowerEdge T40 EMC Installation and Service Manual - Page 84

Environmental specifications

Page 84 highlights

• Intel UHD Graphics 610 for Intel Pentium Gold processor Environmental specifications NOTE: For additional information about environmental certifications, refer to the Product Environmental Datasheet located with the Manuals & Documents on www.dell.com/support/home. Table 31. Temperature specifications Temperature Storage Continuous operation (for altitude less than 900 m or 2953 ft) Fresh air Maximum temperature gradient (operating and storage) Specifications -40-65°C (-40-149°F) 10-35°C (50-95°F) with no direct sunlight on the equipment PowerEdge T40 do not support Fresh air (Expanded operating temperature) 20°C/h (36°F/h) Table 32. Relative humidity specifications Relative humidity Storage Operating Specifications 5% to 95% RH with 27°C (80.6°F) maximum dew point. Atmosphere must be noncondensing at all times. 20% to 80% RH with 21°C ( 69.8 °F ) maximum dew point. Table 33. Maximum vibration specifications Maximum vibration Operating Storage Table 34. Maximum shock pulse specifications Maximum shock pulse Operating Storage Specifications 0.26 Grms at 5 Hz to 350 Hz (all operation orientations) 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) Specifications Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6G for up to 11 ms. Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms. Table 35. Maximum altitude specifications Maximum altitude Operating Storage Specifications 3048 m (10,000 ft) 12,000 m (39,370 ft) Table 36. Operating temperature derating specifications Operating temperature derating Specifications Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft), above 900 m (2,953 ft). 84 Technical specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95

Intel UHD Graphics 610 for Intel Pentium Gold processor
Environmental specifications
NOTE:
For additional information about environmental certifications, refer to the
Product Environmental Datasheet
located with the Manuals & Documents on
www.dell.com/support/home
.
Table 31. Temperature specifications
Temperature
Specifications
Storage
-40–65°C (-40–149°F)
Continuous operation (for altitude less than 900 m
or 2953 ft)
10–35°C (50–95°F) with no direct sunlight on the equipment
Fresh air
PowerEdge T40 do not support Fresh air (Expanded operating temperature)
Maximum temperature gradient (operating and
storage)
20°C/h (36°F/h)
Table 32. Relative humidity specifications
Relative humidity
Specifications
Storage
5% to 95% RH with 27°C (80.6°F) maximum dew point.
Atmosphere must be noncondensing at all times.
Operating
20% to 80% RH with 21°C ( 69.8 °F ) maximum dew point.
Table 33. Maximum vibration specifications
Maximum vibration
Specifications
Operating
0.26 G
rms
at 5 Hz to 350 Hz (all operation orientations)
Storage
1.88 G
rms
at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Table 34. Maximum shock pulse specifications
Maximum shock pulse
Specifications
Operating
Six consecutively executed shock pulses in the positive and negative x, y, and z
axis of 6G for up to 11 ms.
Storage
Six consecutively executed shock pulses in the positive and negative x, y, and z
axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Table 35. Maximum altitude specifications
Maximum altitude
Specifications
Operating
3048 m (10,000 ft)
Storage
12,000 m (39,370 ft)
Table 36. Operating temperature derating specifications
Operating temperature derating
Specifications
Up to 35°C (95°F)
Maximum temperature is reduced by 1°C/300 m (1°F/547 ft), above 900 m
(2,953 ft).
84