Dell PowerStore 9000X EMC PowerStore Alerts and Events Reference Guide - Page 10
SYM. Check IP network
View all Dell PowerStore 9000X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
Alert and Event Messages Event code Severity Alert raised Call home 0x00300D02 MINOR FALSE FALSE 0x00300D03 MINOR FALSE FALSE 0x00300D04 MINOR FALSE FALSE 0x00300D05 CRITICAL TRUE TRUE 0x00300D06 CRITICAL TRUE 0x00300D07 MINOR TRUE 0x00300D08 CRITICAL TRUE TRUE TRUE TRUE 0x00300D09 MAJOR TRUE FALSE 0x00300D0B CRITICAL TRUE 0x00300D0C CRITICAL TRUE 0x00300D0D MAJOR FALSE 0x00300E04 MAJOR TRUE 0x00300E06 MAJOR TRUE 0x00300E07 MAJOR TRUE TRUE TRUE FALSE TRUE TRUE TRUE Message Cluster state was changed from %(old_value) to %(sys_state). Cluster state was changed from %(old_value) to %(sys_state). Cluster state was changed from %(old_value) to %(sys_state). The cluster service is stopping. Stop reason is: %(stopped_reason). The cluster service has stopped. Stopped type is: %(sys_stop_type), stopped reason is: %(stopped_reason). The cluster is in the process of starting. The cluster initialization has failed. The cluster state cannot be determined. The XMS is unable to obtain the cluster state. The cluster state is down. The cluster service has failed to stop. Cluster state was changed from %(old_value) to %(sys_state). Cluster stop failure. Cluster service stop is in progress. Cluster stop is in progress. Repair flow - - - - - This may indicate a failure during the creation of the cluster. The XMS cannot communicate with the cluster manager (SYM). No response to XMS management poll to the SYM. Check IP network and IP reliability using the management port statistics. Cluster has determined that it is down. Expansion Enclosure failure may cause the cluster to be down. - - Failure during cluster service stop. The cluster is performing an unorderly system stop. - System impact - - - The cluster is not servicing IOs. The cluster is not servicing IOs. The cluster has failed to start and is not servicing IOs. The XMS cannot communicate with the cluster manager. The cluster may still be servicing IOs. The cluster is not servicing IOs. The cluster is not servicing IOs. - Cluster may not be servicing IOs. The cluster is in the process of stopping data services. The cluster is in the process of stopping data services. Cluster will not service IOs. 10 Dell EMC PowerStore Events and Alerts Reference Guide Knowledge Base Article - - - https://www.dell.com/support /Article/SLN317203 https://www.dell.com/support /Article/SLN317203 https://www.dell.com/support /Article/SLN317203 https://www.dell.com/support /Article/SLN317203 https://www.dell.com/support /Article/SLN317203 https://www.dell.com/support /Article/SLN317203 https://www.dell.com/support /Article/SLN317203 https://www.dell.com/support /Article/SLN317203 https://www.dell.com/support /Article/SLN317203 https://www.dell.com/support /Article/SLN317203