Dell PowerStore 9000X EMC PowerStore Alerts and Events Reference Guide - Page 68

Article/SLN317194, Article/SLN317199

Page 68 highlights

Alert and Event Messages Event code Severity Alert raised Call home 0x00F00204 INFO FALSE FALSE 0x00F00205 MAJOR TRUE FALSE 0x00F00207 INFO 0x00F00208 INFO 0x00F00209 INFO FALSE TRUE FALSE FALSE FALSE FALSE 0x00F0020A CRITICAL TRUE TRUE 0x00F00301 INFO 0x00F00302 INFO 0x00F00303 INFO FALSE FALSE TRUE FALSE FALSE FALSE 0x00F00304 INFO FALSE FALSE 0x00F00305 MAJOR TRUE FALSE 0x00F00307 INFO 0x00F00308 INFO FALSE TRUE FALSE FALSE Message The host system %(mgmt_address) has been removed successfully. The host system %(mgmt_address) is in a degraded state. Host system %(mgmt_address) is in the normal state. The host system %(mgmt_address) refresh has failed. The host system %(mgmt_address) refresh has completed successfully. The host system %(mgmt_address) operation has failed. The remote system %(mgmt_address) addition has failed. The remote system %(mgmt_address) addition completed successfully. The remote system %(mgmt_address) removal has failed. The remote system %(mgmt_address) removal has completed successfully. The remote system %(mgmt_address) is in a degraded state. The remote system %(mgmt_address) is in the normal state. The remote system %(mgmt_address) volume Repair flow - Verify that the host multipath software and host agent software are running on the host and if the problem still persists please contact Dell support. - Verify connectivity to the host system. - Internal error during pathflip operation, Host reboot is required to recover. Once the reboot is done, do a host refresh. Verify connectivity to the remote system. - Verify connectivity to the remote system, and that there is no import session in progress. - Verify the status of the remote system. Before starting an import, please run "verify and update" from UI under import external storage on source array. - Verify connectivity to the remote system. System impact - - Host applications might have been impacted due to I/O failures. - - - - 68 Dell EMC PowerStore Events and Alerts Reference Guide Knowledge Base Article - https://www.dell.com/support /Article/SLN317194 - https://www.dell.com/support /Article/SLN317194 - - https://www.dell.com/support /Article/SLN317199 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119

Alert and Event Messages
68
Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert raised
Call home
Message
Repair flow
System impact
Knowledge Base Article
0x00F00204
INFO
FALSE
FALSE
The host system
%(mgmt_address) has
been removed successfully.
-
-
-
0x00F00205
MAJOR
TRUE
FALSE
The host system
%(mgmt_address) is in a
degraded state.
Verify that the host
multipath software and host
agent software are running
on the host and if the
problem still persists please
contact Dell support.
-
/Article/SLN317194
0x00F00207
INFO
FALSE
FALSE
Host system
%(mgmt_address) is in the
normal state.
-
-
-
0x00F00208
INFO
TRUE
FALSE
The host system
%(mgmt_address) refresh
has failed.
Verify connectivity to the
host system.
-
-
0x00F00209
INFO
FALSE
FALSE
The host system
%(mgmt_address) refresh
has completed
successfully.
-
-
-
0x00F0020A
CRITICAL
TRUE
TRUE
The host system
%(mgmt_address)
operation has failed.
Internal error during path-
flip operation, Host reboot
is required to recover. Once
the reboot is done, do a
host refresh.
Host applications might
have been impacted due to
I/O failures.
/Article/SLN317194
0x00F00301
INFO
FALSE
FALSE
The remote system
%(mgmt_address) addition
has failed.
Verify connectivity to the
remote system.
-
-
0x00F00302
INFO
FALSE
FALSE
The remote system
%(mgmt_address) addition
completed successfully.
-
-
-
0x00F00303
INFO
TRUE
FALSE
The remote system
%(mgmt_address) removal
has failed.
Verify connectivity to the
remote system, and that
there is no import session
in progress.
-
-
0x00F00304
INFO
FALSE
FALSE
The remote system
%(mgmt_address) removal
has completed
successfully.
-
-
-
0x00F00305
MAJOR
TRUE
FALSE
The remote system
%(mgmt_address) is in a
degraded state.
Verify the status of the
remote system.
Before
starting an import, please
run "verify and update" from
UI under import external
storage on source array.
-
/Article/SLN317199
0x00F00307
INFO
FALSE
FALSE
The remote system
%(mgmt_address) is in the
normal state.
-
-
-
0x00F00308
INFO
TRUE
FALSE
The remote system
%(mgmt_address) volume
Verify connectivity to the
remote system.
-
-