Dell PowerStore 9000X EMC PowerStore Alerts and Events Reference Guide - Page 15
The Node has failed. Use
View all Dell PowerStore 9000X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Alert and Event Messages Event code Severity Alert raised Call home 0x00302B0A MAJOR FALSE FALSE 0x00302E01 NONE FALSE FALSE 0x00303506 MAJOR TRUE 0x00303E05 MAJOR 0x00303E06 MAJOR 0x00303F05 MAJOR 0x00303F06 MAJOR TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE 0x00304001 NONE FALSE FALSE 0x00304002 MINOR TRUE FALSE 0x00304003 CRITICAL TRUE TRUE 0x00304004 MINOR 0x00304202 MAJOR 0x00304203 MAJOR 0x00304302 MAJOR FALSE TRUE TRUE TRUE 0x00304303 INFO FALSE FALSE FALSE FALSE FALSE FALSE Message The Node is not configured as part of the cluster. Node is waiting for activation. SAS port 1 rate changed from %(old_value) to %(sas1_port_rate) IPMI reported abnormal voltage levels. SAS port 1 link is faulty. SAS port 1 link is faulty. SAS port 2 link is faulty. SAS port 2 link is faulty. Node front panel temperature sensor state has changed from %(old_value) to %(node_fp_temperature_st ate). Temperature of the node or one of its components is getting high. Node temperature is critically high. The node temperature sensor is reporting an invalid status. Node has stopped gracefully. Node has stopped. The Node was deactivated (disabled) by user request. The Node has been deactivated by the cluster. Reason for deactivation is %(system_disabled_reason ) Repair flow - The Node has failed. Use the Service and Installation guide to identify and replace the faulty component. - - Check your environmental controls. Check your environmental controls. Check for hardware-related alerts and take appropriate action. - - - System impact - - - - - If high temperatures persist, the node may shut down. There is no impact on the cluster as long as the peer node within the appliance is healthy. In case both nodes experience this issue, the appliance will shut down. - - - Knowledge Base Article https://www.dell.com/support /Article/SLN317238 - https://www.dell.com/support /Article/SLN317251 https://www.dell.com/support /Article/SLN317248 https://www.dell.com/support /Article/SLN317248 https://www.dell.com/support /Article/SLN317248 https://www.dell.com/support /Article/SLN317248 - - https://www.dell.com/support /Article/SLN317238 - https://www.dell.com/support /Article/SLN317236 https://www.dell.com/support /Article/SLN317238 https://www.dell.com/support /Article/SLN317236 https://www.dell.com/support /Article/SLN317236 15 Dell EMC PowerStore Events and Alerts Reference Guide