Dell PowerStore 9000X EMC PowerStore Alerts and Events Reference Guide - Page 89
Article/SLN317215
View all Dell PowerStore 9000X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 89 highlights
Alert and Event Messages Event code Severity Alert raised Call home 0x01800801 INFO FALSE 0x01800802 MAJOR TRUE 0x01800901 INFO FALSE FALSE FALSE FALSE 0x01800902 MAJOR TRUE 0x01800A01 INFO FALSE FALSE FALSE 0x01800A02 MAJOR TRUE FALSE 0x01800B01 INFO FALSE FALSE 0x01800B02 MAJOR TRUE FALSE 0x01800C01 INFO 0x01800C02 MINOR FALSE FALSE 0x01800C03 MAJOR TRUE 0x01800D01 INFO FALSE FALSE FALSE FALSE FALSE Message Ethernet switch %(physical_switch_id). Data ports are connected properly to the Ethernet switches. Data ports are connected to the out of band management switch: %(connection_scheme). Node ports are properly connected to different switches. Node ports are connected to the same Ethernet switch: %(connection_scheme). Node port cabling order is correct. Order of node port cabling is not correct: %(connection_scheme). Partner data ports are properly connected to different Ethernet switches. Partner data ports are connected to the same physical switch: %(connection_scheme). Appliance nodes are connected to Ethernet switches of the same model. Unable to obtain Ethernet switch model information. Nodes are connected to Ethernet switches of different models: %(physical_switch_models) . Appliance nodes are properly connected to Repair flow connecting this port to an out of band management switch. - Check cabling of the node and connect these ports to the main Ethernet switches. - Check cabling of the node and ensure that the ports are connected to different switches to avoid a single point of failure. - Check cabling of the node and ensure that the ports are connected to different Ethernet switches in alternating fashion to ensure high network availability. - Check the cabling of the appliance and ensure that data ports of each node are connected to different physical switches to avoid a single point of failure. - - It is recommended that you use the same Ethernet switch models with an appliance. - System impact Performance or connectivity may be degraded. - - - - - 89 Dell EMC PowerStore Events and Alerts Reference Guide Knowledge Base Article https://www.dell.com/support /Article/SLN317215 https://www.dell.com/support /Article/SLN317215 - https://www.dell.com/support /Article/SLN317215 - https://www.dell.com/support https://www.dell.com/support -