Dell PowerStore 9000X EMC PowerStore Alerts and Events Reference Guide - Page 105

The required VLAN ID is

Page 105 highlights

Alert and Event Messages Event code Severity Alert raised Call home 0x01804601 INFO FALSE FALSE 0x01804602 MAJOR TRUE FALSE 0x01804701 INFO FALSE FALSE 0x01804702 MINOR FALSE FALSE 0x01804703 MAJOR TRUE FALSE 0x01804801 INFO FALSE FALSE 0x01804802 MAJOR TRUE FALSE 0x01804901 INFO FALSE FALSE Message The storage initiator port group %(pg_name) is configured on the Distributed Virtual Switch %(dvs_name). Unable to find a storage initiator port group with name %(pg_name) on the Distributed Virtual Switch %(dvs_name). VLAN configuration on the storage initiator port group %(pg_name) is correct. Unable to obtain information about the VLAN configuration of the storage initiator port group %(pg_name) on the Distributed Virtual Switch %(dvs_name). The storage initiator port group %(pg_name) has an invalid VLAN ID %(vlan_id). The required VLAN ID is %(required_vlan_id). The storage target port group %(pg_name) is configured on the Distributed Virtual Switch %(dvs_name). Unable to find a storage target port group with name %(pg_name) on the Distributed Virtual Switch %(dvs_name). VLAN configuration on the storage target port group %(pg_name) is correct. Repair flow - Configure a storage initiator port group on the Distributed Virtual Switch in vCenter based on the system requirements described in the Virtualization with PowerStore Guide. If the issue persists, contact your service provider. - - Configure the VLAN ID in vCenter. - Configure a storage target port group on the Distributed Virtual Switch in vCenter based on the system requirements described in the Virtualization with PowerStore Guide. If the issue persists, contact your service provider. - System impact - - - 105 Dell EMC PowerStore Events and Alerts Reference Guide Knowledge Base Article - - -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119

Alert and Event Messages
105
Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert raised
Call home
Message
Repair flow
System impact
Knowledge Base Article
0x01804601
INFO
FALSE
FALSE
The storage initiator port
group %(pg_name) is
configured on the
Distributed Virtual Switch
%(dvs_name).
-
-
-
0x01804602
MAJOR
TRUE
FALSE
Unable to find a storage
initiator port group with
name %(pg_name) on the
Distributed Virtual Switch
%(dvs_name).
Configure a storage initiator
port group on the
Distributed Virtual Switch in
vCenter based on the
system requirements
described in the
Virtualization with
PowerStore Guide. If the
issue persists, contact your
service provider.
-
-
0x01804701
INFO
FALSE
FALSE
VLAN configuration on the
storage initiator port group
%(pg_name) is correct.
-
-
-
0x01804702
MINOR
FALSE
FALSE
Unable to obtain
information about the VLAN
configuration of the storage
initiator port group
%(pg_name) on the
Distributed Virtual Switch
%(dvs_name).
-
-
-
0x01804703
MAJOR
TRUE
FALSE
The storage initiator port
group %(pg_name) has an
invalid VLAN ID %(vlan_id).
The required VLAN ID is
%(required_vlan_id).
Configure the VLAN ID in
vCenter.
-
-
0x01804801
INFO
FALSE
FALSE
The storage target port
group %(pg_name) is
configured on the
Distributed Virtual Switch
%(dvs_name).
-
-
-
0x01804802
MAJOR
TRUE
FALSE
Unable to find a storage
target port group with name
%(pg_name) on the
Distributed Virtual Switch
%(dvs_name).
Configure a storage target
port group on the
Distributed Virtual Switch in
vCenter based on the
system requirements
described in the
Virtualization with
PowerStore Guide. If the
issue persists, contact your
service provider.
-
-
0x01804901
INFO
FALSE
FALSE
VLAN configuration on the
storage target port group
%(pg_name) is correct.
-
-
-