Dell PowerStore 9000X EMC PowerStore Alerts and Events Reference Guide - Page 41

Service and Installation

Page 41 highlights

Alert and Event Messages Event code Severity Alert raised Call home 0x0030A204 MAJOR TRUE FALSE 0x0030A205 MAJOR TRUE FALSE 0x0030A206 MINOR TRUE FALSE 0x0030A303 MAJOR TRUE TRUE 0x0030A401 NONE 0x0030A402 NONE 0x0030A403 NONE 0x0030A404 NONE 0x0030A405 NONE 0x0030A406 NONE 0x0030A407 NONE 0x0030A408 NONE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE Message Component part number %(part_number) does not match with the expected part number %(expected_part_number) for this slot. Component serial number is not readable by the software. An unexpected component was found. InternalBatteryBackupModu le's energy required setting is not set at expected value. Port speed has changed from %(old_value) to %(port_speed). Port speed has changed from %(old_value) to %(port_speed). Port speed has changed from %(old_value) to %(port_speed). Port speed has changed from %(old_value) to %(port_speed). Port speed has changed from %(old_value) to %(port_speed). Port speed has changed from %(old_value) to %(port_speed). Port speed has changed from %(old_value) to %(port_speed). Port speed has changed from %(old_value) to %(port_speed). Repair flow The inserted component is different from the previously installed component. Replace it with a compatible component. Refer to the Installation and Service Guide. The component could not be identified. Refer to the Installation and Service Guide for more information on replacing the faulted component. A component has been found in a previously empty slot. Remove the component from the slot. Initialization of InternalBatteryBackupModu le has failed. Use the Service and Installation guide to identify and replace the faulty component. - - - - - - - - System impact Performance may be degraded. Performance may be degraded. No impact. - - 41 Dell EMC PowerStore Events and Alerts Reference Guide Knowledge Base Article https://www.dell.com/support /Article/SLN317221 https://www.dell.com/support /Article/SLN317221 - https://www.dell.com/support /Article/SLN317213 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119

Alert and Event Messages
41
Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert raised
Call home
Message
Repair flow
System impact
Knowledge Base Article
0x0030A204
MAJOR
TRUE
FALSE
Component part number
%(part_number) does not
match with the expected
part number
%(expected_part_number)
for this slot.
The inserted component is
different from the previously
installed component.
Replace it with a
compatible component.
Refer to the Installation and
Service Guide.
Performance may be
degraded.
/Article/SLN317221
0x0030A205
MAJOR
TRUE
FALSE
Component serial number
is not readable by the
software.
The component could not
be identified. Refer to the
Installation and Service
Guide for more information
on replacing the faulted
component.
Performance may be
degraded.
/Article/SLN317221
0x0030A206
MINOR
TRUE
FALSE
An unexpected component
was found.
A component has been
found in a previously empty
slot. Remove the
component from the slot.
No impact.
-
0x0030A303
MAJOR
TRUE
TRUE
InternalBatteryBackupModu
le's energy required setting
is not set at expected
value.
Initialization of
InternalBatteryBackupModu
le has failed.
Use the
Service and Installation
guide to identify and
replace the faulty
component.
-
/Article/SLN317213
0x0030A401
NONE
FALSE
FALSE
Port speed has changed
from %(old_value) to
%(port_speed).
-
-
-
0x0030A402
NONE
FALSE
FALSE
Port speed has changed
from %(old_value) to
%(port_speed).
-
-
-
0x0030A403
NONE
FALSE
FALSE
Port speed has changed
from %(old_value) to
%(port_speed).
-
-
-
0x0030A404
NONE
FALSE
FALSE
Port speed has changed
from %(old_value) to
%(port_speed).
-
-
-
0x0030A405
NONE
FALSE
FALSE
Port speed has changed
from %(old_value) to
%(port_speed).
-
-
-
0x0030A406
NONE
FALSE
FALSE
Port speed has changed
from %(old_value) to
%(port_speed).
-
-
-
0x0030A407
NONE
FALSE
FALSE
Port speed has changed
from %(old_value) to
%(port_speed).
-
-
-
0x0030A408
NONE
FALSE
FALSE
Port speed has changed
from %(old_value) to
%(port_speed).
-
-
-