Dell PowerStore 9000X EMC PowerStore Alerts and Events Reference Guide - Page 23
enclosure_slot has
View all Dell PowerStore 9000X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Alert and Event Messages Event code Severity Alert raised Call home 0x00306F03 MINOR TRUE TRUE 0x00306F04 MINOR TRUE TRUE 0x00306F05 MAJOR TRUE TRUE 0x00306F06 MAJOR TRUE TRUE 0x00307001 MINOR FALSE FALSE 0x00307002 MAJOR TRUE TRUE 0x00307003 MAJOR TRUE TRUE 0x00307101 INFO FALSE FALSE Message %(encl_num) slot %(enclosure_slot) cannot be determined. The drive state is unknown. Cluster diagnostics detected a minor problem in link 2 of drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). Cluster diagnostics detected a problem in link 2 of drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). Cluster diagnostics detected a major problem in link 2 of drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). Cluster diagnostics detected a critical problem in link 2 of drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). The enabled state for drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) has changed from %(old_value) to %(enabled_state). Drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) was manually disabled by user request. The cluster has disabled the drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). It will no longer be in service. Drive lifecycle state in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) has Repair flow - - - - Verify in logs that are no issues. Consider replacing the drive. Verify in logs that are no issues. Consider replacing the drive. - 23 Dell EMC PowerStore Events and Alerts Reference Guide System impact or link 1 is functional impact on cluster is minimal. Cluster performance may be degraded. As long as the other Node link is working as expected or link 1 is functional impact on cluster is minimal. Cluster performance may be degraded. As long as the other Node link is working as expected or link 1 is functional impact on cluster is minimal. Cluster performance may be degraded. As long as the other Node link is working as expected or link 1 is functional impact on cluster is minimal. Cluster performance may be degraded. As long as the other Node link is working as expected or link 1 is functional impact on cluster is minimal. Cluster performance may be degraded. Knowledge Base Article - - https://www.dell.com/support /Article/SLN317218 https://www.dell.com/support /Article/SLN317218 - - Drive will not be used in the https://www.dell.com/support DPG group. /Article/SLN317218 Drive will not be used in the https://www.dell.com/support DPG group. /Article/SLN317218 - -