Dell PowerStore 9000X EMC PowerStore Alerts and Events Reference Guide - Page 23

enclosure_slot has

Page 23 highlights

Alert and Event Messages Event code Severity Alert raised Call home 0x00306F03 MINOR TRUE TRUE 0x00306F04 MINOR TRUE TRUE 0x00306F05 MAJOR TRUE TRUE 0x00306F06 MAJOR TRUE TRUE 0x00307001 MINOR FALSE FALSE 0x00307002 MAJOR TRUE TRUE 0x00307003 MAJOR TRUE TRUE 0x00307101 INFO FALSE FALSE Message %(encl_num) slot %(enclosure_slot) cannot be determined. The drive state is unknown. Cluster diagnostics detected a minor problem in link 2 of drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). Cluster diagnostics detected a problem in link 2 of drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). Cluster diagnostics detected a major problem in link 2 of drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). Cluster diagnostics detected a critical problem in link 2 of drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). The enabled state for drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) has changed from %(old_value) to %(enabled_state). Drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) was manually disabled by user request. The cluster has disabled the drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). It will no longer be in service. Drive lifecycle state in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) has Repair flow - - - - Verify in logs that are no issues. Consider replacing the drive. Verify in logs that are no issues. Consider replacing the drive. - 23 Dell EMC PowerStore Events and Alerts Reference Guide System impact or link 1 is functional impact on cluster is minimal. Cluster performance may be degraded. As long as the other Node link is working as expected or link 1 is functional impact on cluster is minimal. Cluster performance may be degraded. As long as the other Node link is working as expected or link 1 is functional impact on cluster is minimal. Cluster performance may be degraded. As long as the other Node link is working as expected or link 1 is functional impact on cluster is minimal. Cluster performance may be degraded. As long as the other Node link is working as expected or link 1 is functional impact on cluster is minimal. Cluster performance may be degraded. Knowledge Base Article - - https://www.dell.com/support /Article/SLN317218 https://www.dell.com/support /Article/SLN317218 - - Drive will not be used in the https://www.dell.com/support DPG group. /Article/SLN317218 Drive will not be used in the https://www.dell.com/support DPG group. /Article/SLN317218 - -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119

Alert and Event Messages
23
Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert raised
Call home
Message
Repair flow
System impact
Knowledge Base Article
%(encl_num) slot
%(enclosure_slot) cannot
be determined. The drive
state is unknown.
or link 1 is functional impact
on cluster is minimal.
Cluster performance may
be degraded.
0x00306F03
MINOR
TRUE
TRUE
Cluster diagnostics
detected a minor problem
in link 2 of drive in bus
%(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot).
-
As long as the other Node
link is working as expected
or link 1 is functional impact
on cluster is minimal.
Cluster performance may
be degraded.
-
0x00306F04
MINOR
TRUE
TRUE
Cluster diagnostics
detected a problem in link 2
of drive in bus %(bus_num)
enclosure %(encl_num) slot
%(enclosure_slot).
-
As long as the other Node
link is working as expected
or link 1 is functional impact
on cluster is minimal.
Cluster performance may
be degraded.
-
0x00306F05
MAJOR
TRUE
TRUE
Cluster diagnostics
detected a major problem
in link 2 of drive in bus
%(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot).
-
As long as the other Node
link is working as expected
or link 1 is functional impact
on cluster is minimal.
Cluster performance may
be degraded.
/Article/SLN317218
0x00306F06
MAJOR
TRUE
TRUE
Cluster diagnostics
detected a critical problem
in link 2 of drive in bus
%(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot).
-
As long as the other Node
link is working as expected
or link 1 is functional impact
on cluster is minimal.
Cluster performance may
be degraded.
/Article/SLN317218
0x00307001
MINOR
FALSE
FALSE
The enabled state for drive
in bus %(bus_num)
enclosure %(encl_num) slot
%(enclosure_slot) has
changed from %(old_value)
to %(enabled_state).
-
-
-
0x00307002
MAJOR
TRUE
TRUE
Drive in bus %(bus_num)
enclosure %(encl_num) slot
%(enclosure_slot) was
manually disabled by user
request.
Verify in logs that are no
issues. Consider replacing
the drive.
Drive will not be used in the
DPG group.
/Article/SLN317218
0x00307003
MAJOR
TRUE
TRUE
The cluster has disabled
the drive in bus
%(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot). It will no
longer be in service.
Verify in logs that are no
issues. Consider replacing
the drive.
Drive will not be used in the
DPG group.
/Article/SLN317218
0x00307101
INFO
FALSE
FALSE
Drive lifecycle state in bus
%(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot) has
-
-
-