Alert and Event Messages Event code Severity Alert raised Call home 0x01802302 MAJOR TRUE FALSE 0x01802401 INFO FALSE FALSE 0x01802402 MAJOR TRUE FALSE 0x01802501 INFO FALSE FALSE 0x01802502 MAJOR TRUE FALSE 0x01802601 INFO FALSE FALSE 0x01802602 MAJOR TRUE FALSE 0x01802701 INFO FALSE FALSE 0x01802702 MAJOR TRUE FALSE 0x01802801 INFO FALSE FALSE Message appliance management ports are connected to is consistent. Speed mismatch detected on Ethernet switch ports the appliance management ports are connected to: %(connection_scheme). Speed configuration of Ethernet switch ports the appliance data ports are connected to is consistent. Speed mismatch detected on Ethernet switch ports the appliance data ports are connected to: %(connection_scheme). Speed configuration on appliance management ports across the cluster is consistent. Port speed mismatch detected for the appliance management ports of the cluster: %(connection_scheme). Speed configuration on the appliance data ports across the cluster is consistent. Port speed mismatch detected across the appliance data ports of the cluster: %(connection_scheme). Port %(physical_switch_port_id) on Ethernet switch %(physical_switch_id) is properly configured in trunk/hybrid mode. Port %(physical_switch_port_id) on Ethernet switch %(physical_switch_id) is not configured in trunk/hybrid mode. STP on port %(physical_switch_port_id) of Ethernet switch Repair flow Ensure that the speed is configured consistently on the displayed Ethernet switch ports. - Ensure that the speed is configured consistently on the displayed Ethernet switch ports. - Ensure that the port speed is configured consistently on all physical switches. - Ensure that the port speed is configured consistently on all physical switches. - Configure the port in trunk/hybrid mode. - 96 Dell EMC PowerStore Events and Alerts Reference Guide System impact - - Knowledge Base Article https://www.dell.com/support /Article/SLN317215 - https://www.dell.com/support /Article/SLN317212 - https://www.dell.com/support /Article/SLN317215 https://www.dell.com/support /Article/SLN317215 - https://www.dell.com/support /Article/SLN317215 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119

Alert and Event Messages
96
Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert raised
Call home
Message
Repair flow
System impact
Knowledge Base Article
appliance management
ports are connected to is
consistent.
0x01802302
MAJOR
TRUE
FALSE
Speed mismatch detected
on Ethernet switch ports
the appliance management
ports are connected to:
%(connection_scheme).
Ensure that the speed is
configured consistently on
the displayed Ethernet
switch ports.
-
/Article/SLN317215
0x01802401
INFO
FALSE
FALSE
Speed configuration of
Ethernet switch ports the
appliance data ports are
connected to is consistent.
-
-
-
0x01802402
MAJOR
TRUE
FALSE
Speed mismatch detected
on Ethernet switch ports
the appliance data ports
are connected to:
%(connection_scheme).
Ensure that the speed is
configured consistently on
the displayed Ethernet
switch ports.
-
/Article/SLN317212
0x01802501
INFO
FALSE
FALSE
Speed configuration on
appliance management
ports across the cluster is
consistent.
-
-
-
0x01802502
MAJOR
TRUE
FALSE
Port speed mismatch
detected for the appliance
management ports of the
cluster:
%(connection_scheme).
Ensure that the port speed
is configured consistently
on all physical switches.
-
/Article/SLN317215
0x01802601
INFO
FALSE
FALSE
Speed configuration on the
appliance data ports across
the cluster is consistent.
-
-
-
0x01802602
MAJOR
TRUE
FALSE
Port speed mismatch
detected across the
appliance data ports of the
cluster:
%(connection_scheme).
Ensure that the port speed
is configured consistently
on all physical switches.
-
/Article/SLN317215
0x01802701
INFO
FALSE
FALSE
Port
%(physical_switch_port_id)
on Ethernet switch
%(physical_switch_id) is
properly configured in
trunk/hybrid mode.
-
-
-
0x01802702
MAJOR
TRUE
FALSE
Port
%(physical_switch_port_id)
on Ethernet switch
%(physical_switch_id) is
not configured in
trunk/hybrid mode.
Configure the port in
trunk/hybrid mode.
-
/Article/SLN317215
0x01802801
INFO
FALSE
FALSE
STP on port
%(physical_switch_port_id)
of Ethernet switch
-
-
-