Dell PowerStore 9000X EMC PowerStore Alerts and Events Reference Guide - Page 67
I/O failures.
![]() |
View all Dell PowerStore 9000X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
Alert and Event Messages Event code Severity Alert raised Call home 0x00F00126 MINOR TRUE FALSE 0x00F00127 CRITICAL TRUE TRUE 0x00F00128 MINOR TRUE FALSE 0x00F00129 MINOR TRUE FALSE 0x00F0012A MINOR TRUE FALSE 0x00F0012B MINOR TRUE FALSE 0x00F0012C MINOR TRUE FALSE 0x00F0012D MINOR TRUE 0x00F00201 MAJOR 0x00F00202 INFO 0x00F00203 INFO TRUE FALSE TRUE FALSE FALSE FALSE FALSE Message %(import_session_name) has failed. Import session %(import_session_name) has failed with errors on the host side. Import session %(import_session_name) has failed with errors on the host side. Import session %(import_session_name) has failed with errors on the host side. Import session %(import_session_name) failed with errors on the host side. Import session %(import_session_name) has failed with errors on the host side. Import session %(import_session_name) has failed with errors on the host side. Import session %(import_session_name) has failed with errors on the host side. Import session %(import_session_name) has failed with errors on the host side. Host system %(mgmt_address) addition has failed. Host system %(mgmt_address) has been added successfully. Host system %(mgmt_address) removal has failed. Repair flow System impact Check and resolve the cluster configuration on the hosts. Verify that the host multipath software and host agent software are running on the host and if the problem still persists, host reboot may be required. If the problem still persists please contact Dell support. Please make sure multipath service is running on the host. - Host applications might have been impacted due to I/O failures. - Check the cluster state. - Please check host support matrix to verify whether - host is supported. Verify that the Microsoft Cluster service is running and cluster configuration - status is healthy. Verify that the iSCSI service is running on the - host. Verify that the host cluster configuration state and - make sure it is healthy. Verify connectivity to the host and retry. - - - Verify connectivity to the host, and that no import - sessions are in progress. Knowledge Base Article - https://www.dell.com/support /Article/SLN317196 https://www.dell.com/support /Article/SLN317187 - 67 Dell EMC PowerStore Events and Alerts Reference Guide
![](/manual_guide/products/dell-powerstore-1000t-emc-powerstore-alerts-events-reference-guide-4956a6d/67.png)