Alert and Event Messages Event code Severity Alert raised Call home 0x00305606 MAJOR TRUE TRUE 0x00305701 MINOR FALSE FALSE 0x00305702 MAJOR 0x00305703 MAJOR FALSE FALSE 0x00305801 MINOR FALSE 0x00305802 MINOR 0x00305803 MAJOR FALSE TRUE TRUE TRUE FALSE FALSE TRUE 0x00305804 MAJOR TRUE TRUE 0x00305805 MINOR 0x00305806 MINOR 0x00305807 INFO 0x00305901 NONE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE 0x00305902 NONE FALSE FALSE 0x00305903 MAJOR FALSE FALSE Message Internal M.2 boot module in slot %(slot_num) is not initialized. The enabled state for the internal M.2 boot module has changed from %(old_value) to %(enabled_state). The InternalM.2BootModule was deactivated (disabled) by user request. The cluster has disabled the InternalM.2BootModule. Lifecycle state of the internal M.2 boot module has changed from %(old_value) to %(fru_lifecycle_state). Internal M.2 boot module is initializing. Internal M.2 boot module has faulted. Internal M.2 boot module is disconnected. Internal M.2 boot module is not initialized. Internal M.2 boot module prepare failed. Internal M.2 boot module has been replaced. Node's %(location) power supply unit has a %(power_failure) power status. Node's %(location) power supply unit has a %(power_failure) power status. Node's %(location) power supply unit has a %(power_failure) power status. Repair flow If the issue persists, contact your service provider. - - - - Replace the faulted component. Refer to the Installation and Service Guide for more information. Verify that the internal M.2 boot module is properly seated. If the issue persists, replace the component. Refer to the Installation and Service Guide for more information. - - - - System impact Performance may be degraded. - - - Performance may be degraded. Performance may be degraded. - - - 18 Dell EMC PowerStore Events and Alerts Reference Guide Knowledge Base Article https://www.dell.com/support /Article/SLN317231 - https://www.dell.com/support /Article/SLN317231 https://www.dell.com/support /Article/SLN317231 - https://www.dell.com/support /Article/SLN317231 https://www.dell.com/support /Article/SLN317231 - - - https://www.dell.com/support /Article/SLN317246

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119

Alert and Event Messages
18
Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert raised
Call home
Message
Repair flow
System impact
Knowledge Base Article
0x00305606
MAJOR
TRUE
TRUE
Internal M.2 boot module in
slot %(slot_num) is not
initialized.
If the issue persists, contact
your service provider.
Performance may be
degraded.
/Article/SLN317231
0x00305701
MINOR
FALSE
FALSE
The enabled state for the
internal M.2 boot module
has changed from
%(old_value) to
%(enabled_state).
-
-
-
0x00305702
MAJOR
FALSE
TRUE
The InternalM.2BootModule
was deactivated (disabled)
by user request.
-
-
/Article/SLN317231
0x00305703
MAJOR
FALSE
TRUE
The cluster has disabled
the InternalM.2BootModule.
-
-
/Article/SLN317231
0x00305801
MINOR
FALSE
FALSE
Lifecycle state of the
internal M.2 boot module
has changed from
%(old_value) to
%(fru_lifecycle_state).
-
-
-
0x00305802
MINOR
FALSE
FALSE
Internal M.2 boot module is
initializing.
-
-
-
0x00305803
MAJOR
TRUE
TRUE
Internal M.2 boot module
has faulted.
Replace the faulted
component. Refer to the
Installation and Service
Guide for more information.
Performance may be
degraded.
/Article/SLN317231
0x00305804
MAJOR
TRUE
TRUE
Internal M.2 boot module is
disconnected.
Verify that the internal M.2
boot module is properly
seated. If the issue
persists, replace the
component. Refer to the
Installation and Service
Guide for more information.
Performance may be
degraded.
/Article/SLN317231
0x00305805
MINOR
FALSE
FALSE
Internal M.2 boot module is
not initialized.
-
-
-
0x00305806
MINOR
FALSE
FALSE
Internal M.2 boot module
prepare failed.
-
-
-
0x00305807
INFO
FALSE
FALSE
Internal M.2 boot module
has been replaced.
-
-
-
0x00305901
NONE
FALSE
FALSE
Node's %(location) power
supply unit has a
%(power_failure) power
status.
-
-
-
0x00305902
NONE
FALSE
FALSE
Node's %(location) power
supply unit has a
%(power_failure) power
status.
-
-
-
0x00305903
MAJOR
FALSE
FALSE
Node's %(location) power
supply unit has a
%(power_failure) power
status.
-
-
/Article/SLN317246