Dell PowerStore 9000X EMC PowerStore Alerts and Events Reference Guide - Page 46
Article/SLN317228
View all Dell PowerStore 9000X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
Alert and Event Messages Event code Severity Alert raised Call home 0x0030AD01 MINOR TRUE TRUE 0x0030AD02 NONE FALSE FALSE 0x0030AE01 MAJOR TRUE TRUE 0x0030AE02 NONE FALSE FALSE 0x0030AF01 INFO FALSE FALSE 0x0030AF02 MAJOR TRUE TRUE 0x0030AF03 MAJOR TRUE TRUE 0x0030AF04 MAJOR TRUE TRUE 0x0030AF05 MAJOR TRUE TRUE Message Bus %(bus_num) enclosure %(encl_num) has exceeded the temperature warning threshold. Bus %(bus_num) enclosure %(encl_num) over temperature warning condition has changed from %(old_value) to %(overtempwarning). Bus %(bus_num) enclosure %(encl_num) has exceeded the temperature failure threshold. Bus %(bus_num) enclosure %(encl_num) over temperature failure condition has changed from %(old_value) to %(overtempfailure). The shutdown reason for drives on bus %(bus_num) enclosure %(encl_num) has changed from %(old_value) to %(shutdown_reason). Drives on bus %(bus_num) enclosure %(encl_num) are scheduled to shutdown because of a user-initiated action. Drives on bus %(bus_num) enclosure %(encl_num) are scheduled to shut down because of a critical temperature fault. Drives on bus %(bus_num) enclosure %(encl_num) are scheduled to shut down because of a critical cooling fault. Drives on bus %(bus_num) enclosure %(encl_num) are scheduled to shut down because the power supply is not installed. Repair flow Check the environmental controls. - Check your environmental controls. Check for hardware-related alerts and take appropriate action. - - - Check your environmental controls. If the issue persists, contact your service provider. Check for hardware-related alerts and take appropriate action. If the issue persists, contact your service provider. Check for hardware-related alerts and take appropriate action. If the issue persists, contact your service provider. System impact If the system remains in this condition for a long duration, the drives in the enclosure will shut down. - Drives in the expansion enclosure will shut down. Data availability and performance may be degraded. - - The cluster may not serve IOs. Data availability and performance may be degraded. Data availability and performance may be degraded. Data availability and performance may be degraded. Knowledge Base Article - - https://www.dell.com/support /Article/SLN317228 - - https://www.dell.com/support /Article/SLN317228 https://www.dell.com/support /Article/SLN317228 https://www.dell.com/support /Article/SLN317228 https://www.dell.com/support /Article/SLN317228 46 Dell EMC PowerStore Events and Alerts Reference Guide