Dell PowerStore 9000X EMC PowerStore Alerts and Events Reference Guide - Page 46

Article/SLN317228

Page 46 highlights

Alert and Event Messages Event code Severity Alert raised Call home 0x0030AD01 MINOR TRUE TRUE 0x0030AD02 NONE FALSE FALSE 0x0030AE01 MAJOR TRUE TRUE 0x0030AE02 NONE FALSE FALSE 0x0030AF01 INFO FALSE FALSE 0x0030AF02 MAJOR TRUE TRUE 0x0030AF03 MAJOR TRUE TRUE 0x0030AF04 MAJOR TRUE TRUE 0x0030AF05 MAJOR TRUE TRUE Message Bus %(bus_num) enclosure %(encl_num) has exceeded the temperature warning threshold. Bus %(bus_num) enclosure %(encl_num) over temperature warning condition has changed from %(old_value) to %(overtempwarning). Bus %(bus_num) enclosure %(encl_num) has exceeded the temperature failure threshold. Bus %(bus_num) enclosure %(encl_num) over temperature failure condition has changed from %(old_value) to %(overtempfailure). The shutdown reason for drives on bus %(bus_num) enclosure %(encl_num) has changed from %(old_value) to %(shutdown_reason). Drives on bus %(bus_num) enclosure %(encl_num) are scheduled to shutdown because of a user-initiated action. Drives on bus %(bus_num) enclosure %(encl_num) are scheduled to shut down because of a critical temperature fault. Drives on bus %(bus_num) enclosure %(encl_num) are scheduled to shut down because of a critical cooling fault. Drives on bus %(bus_num) enclosure %(encl_num) are scheduled to shut down because the power supply is not installed. Repair flow Check the environmental controls. - Check your environmental controls. Check for hardware-related alerts and take appropriate action. - - - Check your environmental controls. If the issue persists, contact your service provider. Check for hardware-related alerts and take appropriate action. If the issue persists, contact your service provider. Check for hardware-related alerts and take appropriate action. If the issue persists, contact your service provider. System impact If the system remains in this condition for a long duration, the drives in the enclosure will shut down. - Drives in the expansion enclosure will shut down. Data availability and performance may be degraded. - - The cluster may not serve IOs. Data availability and performance may be degraded. Data availability and performance may be degraded. Data availability and performance may be degraded. Knowledge Base Article - - https://www.dell.com/support /Article/SLN317228 - - https://www.dell.com/support /Article/SLN317228 https://www.dell.com/support /Article/SLN317228 https://www.dell.com/support /Article/SLN317228 https://www.dell.com/support /Article/SLN317228 46 Dell EMC PowerStore Events and Alerts Reference Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119

Alert and Event Messages
46
Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert raised
Call home
Message
Repair flow
System impact
Knowledge Base Article
0x0030AD01
MINOR
TRUE
TRUE
Bus %(bus_num) enclosure
%(encl_num) has
exceeded the temperature
warning threshold.
Check the environmental
controls.
If the system remains in
this condition for a long
duration, the drives in the
enclosure will shut down.
-
0x0030AD02
NONE
FALSE
FALSE
Bus %(bus_num) enclosure
%(encl_num) over
temperature warning
condition has changed from
%(old_value) to
%(overtempwarning).
-
-
-
0x0030AE01
MAJOR
TRUE
TRUE
Bus %(bus_num) enclosure
%(encl_num) has
exceeded the temperature
failure threshold.
Check your environmental
controls. Check for
hardware-related alerts and
take appropriate action.
Drives in the expansion
enclosure will shut down.
Data availability and
performance may be
degraded.
/Article/SLN317228
0x0030AE02
NONE
FALSE
FALSE
Bus %(bus_num) enclosure
%(encl_num) over
temperature failure
condition has changed from
%(old_value) to
%(overtempfailure).
-
-
-
0x0030AF01
INFO
FALSE
FALSE
The shutdown reason for
drives on bus %(bus_num)
enclosure %(encl_num)
has changed from
%(old_value) to
%(shutdown_reason).
-
-
-
0x0030AF02
MAJOR
TRUE
TRUE
Drives on bus %(bus_num)
enclosure %(encl_num) are
scheduled to shutdown
because of a user-initiated
action.
-
The cluster may not serve
IOs.
/Article/SLN317228
0x0030AF03
MAJOR
TRUE
TRUE
Drives on bus %(bus_num)
enclosure %(encl_num) are
scheduled to shut down
because of a critical
temperature fault.
Check your environmental
controls. If the issue
persists, contact your
service provider.
Data availability and
performance may be
degraded.
/Article/SLN317228
0x0030AF04
MAJOR
TRUE
TRUE
Drives on bus %(bus_num)
enclosure %(encl_num) are
scheduled to shut down
because of a critical cooling
fault.
Check for hardware-related
alerts and take appropriate
action. If the issue persists,
contact your service
provider.
Data availability and
performance may be
degraded.
/Article/SLN317228
0x0030AF05
MAJOR
TRUE
TRUE
Drives on bus %(bus_num)
enclosure %(encl_num) are
scheduled to shut down
because the power supply
is not installed.
Check for hardware-related
alerts and take appropriate
action. If the issue persists,
contact your service
provider.
Data availability and
performance may be
degraded.
/Article/SLN317228