Dell PowerStore 9000X EMC PowerStore Alerts and Events Reference Guide - Page 25
Contact Dell EMC
View all Dell PowerStore 9000X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Alert and Event Messages Event code Severity Alert raised Call home 0x00307204 MINOR TRUE TRUE 0x00307301 INFO FALSE FALSE 0x00307302 MAJOR TRUE TRUE 0x00307303 MAJOR TRUE TRUE 0x00307304 MAJOR TRUE 0x00307401 INFO 0x00307402 0x00307403 INFO INFO FALSE FALSE FALSE TRUE FALSE FALSE FALSE 0x00307404 MAJOR TRUE TRUE 0x00307405 MINOR TRUE FALSE 0x00307701 MAJOR TRUE TRUE Message enclosure %(encl_num) slot %(enclosure_slot) is incompatible. Firmware version of the drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) is incorrect. Drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) has changed from %(old_value) to %(dieh_action_state). Drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) has failed. Drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) associated data have been resulted. Drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) needs replacement. Port state has changed from %(old_value) to %(port_state). Port link is down but not in use. Port link status is unknown. Port link is down. Port link speed in each node of the appliance do not match. XENV is not active. Repair flow upgrade logs and escalate to L3, as required. This indicates a failed FW upgrade on the drive. Verify upgrade logs and escalate to L3, as required. - Verify that there are no related alerts. You may need to replace the drive. Please send the resulting files to Dell EMC. Contact Dell EMC to replace the drive. - Check cabling, your SFP connectors, and connectivity to the port. Check for other hardwarerelated alerts and take appropriate action. If the issue persists, contact your service provider. Install identical components on each node of the appliance to ensure that port link speeds match. It is recommended that you always install components in pairs. - System impact Drive will not be used in the DPG group. - Drive is not in service. - Data availability and performance may be degraded. Performance may be degraded. Node may not serve IOs. Knowledge Base Article - - https://www.dell.com/support /Article/SLN317218 https://www.dell.com/support /Article/SLN317218 - https://www.dell.com/support /Article/SLN317237 https://www.dell.com/support /Article/SLN317237 https://www.dell.com/support /Article/SLN317200 25 Dell EMC PowerStore Events and Alerts Reference Guide