Alert and Event Messages Event code Severity Alert raised Call home 0x00306C04 CRITICAL TRUE TRUE 0x00306D01 MINOR FALSE FALSE 0x00306D02 MINOR TRUE TRUE 0x00306D03 MINOR TRUE TRUE 0x00306D04 MINOR TRUE TRUE 0x00306D05 MAJOR TRUE TRUE 0x00306D06 MAJOR TRUE TRUE 0x00306E01 MINOR FALSE FALSE Message Drive endurance level for bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) is exhausted. The remaining wear level for this drive is %(percent_endurance_rem aining)%. Drive diagnostic state for bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) was changed from %(old_value) to %(diagnostic_health_state). State of the drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) cannot be determined. The drive state is unknown. Diagnostics detected a minor problem for drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). Diagnostics detected a problem for drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). Diagnostics detected a major problem for drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). Diagnostics detected a critical problem for drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). Link 1 state for drive in bus %(bus_num) enclosure Repair flow Contact your service provider. - - Indicates that a SMART warning was detected or IO error detected. SMART 5D error has been detected. Please proceed to replace drive. - - System impact Drive will be used until the drive fails. As long as all other drives are healthy, and there still free space to rebuild if another drive fails the impact on cluster is minimal. Cluster performance may be impacted. As long as all other drives are healthy, and there still free space to rebuild if another drive fails the impact on cluster is minimal. Cluster performance may be impacted. As long as all other drives are healthy, and there still free space to rebuild if another drive fails the impact on cluster is minimal. As long as other drives are healthy the impact on cluster is minimal. As long as all other drives are healthy, and there still free space to rebuild if another drive fails the impact on cluster is minimal. As long as all other drives are healthy, and there still free space to rebuild if another drive fails the impact on cluster is minimal. - Knowledge Base Article https://www.dell.com/support /Article/SLN317247 - - - https://www.dell.com/support /Article/SLN317218 https://www.dell.com/support /Article/SLN317218 - 21 Dell EMC PowerStore Events and Alerts Reference Guide