Dell PowerStore 9000X EMC PowerStore Alerts and Events Reference Guide - Page 21

Article/SLN317247, Article/SLN317218

Page 21 highlights

Alert and Event Messages Event code Severity Alert raised Call home 0x00306C04 CRITICAL TRUE TRUE 0x00306D01 MINOR FALSE FALSE 0x00306D02 MINOR TRUE TRUE 0x00306D03 MINOR TRUE TRUE 0x00306D04 MINOR TRUE TRUE 0x00306D05 MAJOR TRUE TRUE 0x00306D06 MAJOR TRUE TRUE 0x00306E01 MINOR FALSE FALSE Message Drive endurance level for bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) is exhausted. The remaining wear level for this drive is %(percent_endurance_rem aining)%. Drive diagnostic state for bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) was changed from %(old_value) to %(diagnostic_health_state). State of the drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) cannot be determined. The drive state is unknown. Diagnostics detected a minor problem for drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). Diagnostics detected a problem for drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). Diagnostics detected a major problem for drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). Diagnostics detected a critical problem for drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). Link 1 state for drive in bus %(bus_num) enclosure Repair flow Contact your service provider. - - Indicates that a SMART warning was detected or IO error detected. SMART 5D error has been detected. Please proceed to replace drive. - - System impact Drive will be used until the drive fails. As long as all other drives are healthy, and there still free space to rebuild if another drive fails the impact on cluster is minimal. Cluster performance may be impacted. As long as all other drives are healthy, and there still free space to rebuild if another drive fails the impact on cluster is minimal. Cluster performance may be impacted. As long as all other drives are healthy, and there still free space to rebuild if another drive fails the impact on cluster is minimal. As long as other drives are healthy the impact on cluster is minimal. As long as all other drives are healthy, and there still free space to rebuild if another drive fails the impact on cluster is minimal. As long as all other drives are healthy, and there still free space to rebuild if another drive fails the impact on cluster is minimal. - Knowledge Base Article https://www.dell.com/support /Article/SLN317247 - - - https://www.dell.com/support /Article/SLN317218 https://www.dell.com/support /Article/SLN317218 - 21 Dell EMC PowerStore Events and Alerts Reference Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119

Alert and Event Messages
21
Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert raised
Call home
Message
Repair flow
System impact
Knowledge Base Article
0x00306C04
CRITICAL
TRUE
TRUE
Drive endurance level for
bus %(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot) is
exhausted. The remaining
wear level for this drive is
%(percent_endurance_rem
aining)%.
Contact your service
provider.
Drive will be used until the
drive fails.
/Article/SLN317247
0x00306D01
MINOR
FALSE
FALSE
Drive diagnostic state for
bus %(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot) was
changed from %(old_value)
to
%(diagnostic_health_state).
-
As long as all other drives
are healthy, and there still
free space to rebuild if
another drive fails the
impact on cluster is
minimal. Cluster
performance may be
impacted.
-
0x00306D02
MINOR
TRUE
TRUE
State of the drive in bus
%(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot) cannot
be determined. The drive
state is unknown.
-
As long as all other drives
are healthy, and there still
free space to rebuild if
another drive fails the
impact on cluster is
minimal. Cluster
performance may be
impacted.
-
0x00306D03
MINOR
TRUE
TRUE
Diagnostics detected a
minor problem for drive in
bus %(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot).
Indicates that a SMART
warning was detected or IO
error detected.
As long as all other drives
are healthy, and there still
free space to rebuild if
another drive fails the
impact on cluster is
minimal.
-
0x00306D04
MINOR
TRUE
TRUE
Diagnostics detected a
problem for drive in bus
%(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot).
SMART 5D error has been
detected. Please proceed
to replace drive.
As long as other drives are
healthy the impact on
cluster is minimal.
-
0x00306D05
MAJOR
TRUE
TRUE
Diagnostics detected a
major problem for drive in
bus %(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot).
-
As long as all other drives
are healthy, and there still
free space to rebuild if
another drive fails the
impact on cluster is
minimal.
/Article/SLN317218
0x00306D06
MAJOR
TRUE
TRUE
Diagnostics detected a
critical problem for drive in
bus %(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot).
-
As long as all other drives
are healthy, and there still
free space to rebuild if
another drive fails the
impact on cluster is
minimal.
/Article/SLN317218
0x00306E01
MINOR
FALSE
FALSE
Link 1 state for drive in bus
%(bus_num) enclosure
-
-
-