Dell PowerStore 9000X EMC PowerStore Alerts and Events Reference Guide - Page 49
The Node DIMM could
View all Dell PowerStore 9000X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
Alert and Event Messages Event code Severity Alert raised 0x0030B509 NONE FALSE Call home FALSE 0x0030B50A NONE FALSE FALSE 0x0030B50B NONE FALSE FALSE 0x0030B601 NONE FALSE FALSE 0x0030B602 MAJOR TRUE FALSE 0x0030B603 MAJOR TRUE FALSE 0x0030B604 MINOR TRUE FALSE 0x0030B701 NONE FALSE FALSE 0x0030B702 MAJOR TRUE 0x0030B901 NONE FALSE 0x0030B902 CRITICAL TRUE FALSE FALSE FALSE Message Clustering agent required action has changed. Clustering agent required action has changed. Clustering agent required action has changed. Compatibility status of the Node DIMM%(dimm_index) was changed from %(old_value) to %(fru_comp_status). Node DIMM%(dimm_index) part number %(part_number) does not match with the expected part number %(expected_part_number) for this slot. Node DIMM%(dimm_index) resume is not readable by the software. Found an unexpected Node DIMM in slot %(dimm_index). Compatibility status of the internal M.2 boot module in slot %(slot_num) has changed from %(old_value) to %(fru_comp_status). Internal M.2 boot module in slot %(slot_num) of size %(size_gb) GB does not meet the minimum required size of %(min_size_gb) GB for this slot. NAS has been repaired. NAS failure detected. Repair flow - - - - The inserted Node DIMM is different from the previously installed DIMM. Remove the DIMM and replace it with a compatible Node DIMM using the Service and Installation guide. The Node DIMM could not be identified. Use the Service and Installation guide to replace the faulty component. Either 1) A DIMM was added into a previously empty slot, which is not supported and should be removed or 2) Some DIMMs have been rearranged in the slots and need to be restored to their original locations. - Replace it with a compatible module. Refer to the Installation and Service Guide for more information. NAS is disabled. Follow procedures to manually bring up NAS nodes or reinstall File. System impact - - - - - Performance may be degraded. File functionality is disabled. The cluster may still be servicing IOs. Knowledge Base Article - - https://www.dell.com/support /Article/SLN317227 https://www.dell.com/support /Article/SLN317227 https://www.dell.com/support /Article/SLN317227 - https://www.dell.com/support /Article/SLN317231 https://www.dell.com/support /Article/SLN317232 49 Dell EMC PowerStore Events and Alerts Reference Guide