Dell PowerStore 9000X EMC PowerStore Alerts and Events Reference Guide - Page 17

Node IPMI BMC connection

Page 17 highlights

Alert and Event Messages Event code Severity Alert raised Call home 0x00305303 MAJOR TRUE TRUE 0x00305402 MAJOR TRUE TRUE 0x00305403 MAJOR TRUE TRUE 0x00305501 NONE FALSE FALSE 0x00305502 NONE FALSE FALSE 0x00305503 MAJOR TRUE TRUE 0x00305601 MINOR FALSE FALSE 0x00305602 MAJOR TRUE TRUE 0x00305603 MAJOR TRUE TRUE 0x00305604 MAJOR TRUE TRUE 0x00305605 MAJOR FALSE FALSE Message Interconnect port 1 has failed. Interconnect port 2 is degraded. Interconnect port 2 has failed. Node IPMI BMC connection state has changed from %(old_value) to %(ipmi_bmc_connected). Node IPMI BMC connection state has changed from %(old_value) to %(ipmi_bmc_connected). Node IPMI BMC connection is no longer active. Internal M.2 boot module in slot %(slot_num) has changed from %(old_value) to %(disk_failure). Internal M.2 boot module slot in %(slot_num) used as %(local_disk_purpose) is empty. InternalM.2BootModule slot %(slot_num) is expected to be empty but contains a disk. Internal M.2 boot module in slot %(slot_num) is not supported. Internal M.2 boot module in slot %(slot_num) has errors or is faulted. Repair flow Check the state of the peer Node. One or both Nodes may need to be restarted or reseated in the BaseEnclosure. Check the state of the peer Node. One or both Nodes may need to be restarted or reseated in the BaseEnclosure. Check the state of the peer Node. One or both Nodes may need to be restarted or reseated in the BaseEnclosure. - - Shut down the node, unseat it from the enclosure, and reseat it again. If the issue persists, contact your service provider. - Refer to the Installation and Service Guide to install a supported Internal M.2 boot module. - Replace it with a supported M.2 boot module. Refer to the Installation and Service Guide for more information. Replace the internal M.2 boot module. Refer to the Installation and Service Guide for more information. System impact Cluster performance may be degraded. Cluster performance may be degraded. Cluster performance may be degraded. - - Hardware monitoring may be degraded. - Performance may be degraded. - Performance may be degraded. Performance may be degraded. 17 Dell EMC PowerStore Events and Alerts Reference Guide Knowledge Base Article https://www.dell.com/support /Article/SLN317241 https://www.dell.com/support /Article/SLN317241 https://www.dell.com/support /Article/SLN317241 - - https://www.dell.com/support /Article/SLN317243 - https://www.dell.com/support /Article/SLN317231 https://www.dell.com/support /Article/SLN317231 https://www.dell.com/support /Article/SLN317231 https://www.dell.com/support /Article/SLN317231

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119

Alert and Event Messages
17
Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert raised
Call home
Message
Repair flow
System impact
Knowledge Base Article
0x00305303
MAJOR
TRUE
TRUE
Interconnect port 1 has
failed.
Check the state of the peer
Node. One or both Nodes
may need to be restarted or
reseated in the
BaseEnclosure.
Cluster performance may
be degraded.
/Article/SLN317241
0x00305402
MAJOR
TRUE
TRUE
Interconnect port 2 is
degraded.
Check the state of the peer
Node. One or both Nodes
may need to be restarted or
reseated in the
BaseEnclosure.
Cluster performance may
be degraded.
/Article/SLN317241
0x00305403
MAJOR
TRUE
TRUE
Interconnect port 2 has
failed.
Check the state of the peer
Node. One or both Nodes
may need to be restarted or
reseated in the
BaseEnclosure.
Cluster performance may
be degraded.
/Article/SLN317241
0x00305501
NONE
FALSE
FALSE
Node IPMI BMC connection
state has changed from
%(old_value) to
%(ipmi_bmc_connected).
-
-
-
0x00305502
NONE
FALSE
FALSE
Node IPMI BMC connection
state has changed from
%(old_value) to
%(ipmi_bmc_connected).
-
-
-
0x00305503
MAJOR
TRUE
TRUE
Node IPMI BMC connection
is no longer active.
Shut down the node,
unseat it from the
enclosure, and reseat it
again. If the issue persists,
contact your service
provider.
Hardware monitoring may
be degraded.
/Article/SLN317243
0x00305601
MINOR
FALSE
FALSE
Internal M.2 boot module in
slot %(slot_num) has
changed from %(old_value)
to %(disk_failure).
-
-
-
0x00305602
MAJOR
TRUE
TRUE
Internal M.2 boot module
slot in %(slot_num) used as
%(local_disk_purpose) is
empty.
Refer to the Installation and
Service Guide to install a
supported Internal M.2 boot
module.
Performance may be
degraded.
/Article/SLN317231
0x00305603
MAJOR
TRUE
TRUE
InternalM.2BootModule slot
%(slot_num) is expected to
be empty but contains a
disk.
-
-
/Article/SLN317231
0x00305604
MAJOR
TRUE
TRUE
Internal M.2 boot module in
slot %(slot_num) is not
supported.
Replace it with a supported
M.2 boot module. Refer to
the Installation and Service
Guide for more information.
Performance may be
degraded.
/Article/SLN317231
0x00305605
MAJOR
FALSE
FALSE
Internal M.2 boot module in
slot %(slot_num) has errors
or is faulted.
Replace the internal M.2
boot module. Refer to the
Installation and Service
Guide for more information.
Performance may be
degraded.
/Article/SLN317231