Dell PowerStore 9000X EMC PowerStore Alerts and Events Reference Guide - Page 44

SAS connector B on Bus

Page 44 highlights

Alert and Event Messages Event code Severity Alert raised Call home 0x0030A803 MINOR TRUE FALSE 0x0030A804 MINOR TRUE FALSE 0x0030A805 INFO TRUE FALSE 0x0030A806 INFO TRUE FALSE 0x0030A807 MAJOR TRUE FALSE 0x0030A901 NONE 0x0030A902 MAJOR 0x0030AA01 NONE FALSE TRUE FALSE FALSE FALSE FALSE 0x0030AA02 NONE 0x0030AA03 MINOR FALSE TRUE 0x0030AA04 MAJOR TRUE FALSE FALSE FALSE 0x0030AB01 NONE FALSE FALSE Message from %(old_value) to %(sas2_cable_status). SAS connector B on Bus %(bus_num) Enclosure %(encl_num) %(identification) is degraded. SAS connector B on Bus %(bus_num) Enclosure %(encl_num) %(identification) is disabled. SAS connector B on Bus %(bus_num) Enclosure %(encl_num) %(identification) is missing. SAS connector B on Bus %(bus_num) Enclosure %(encl_num) %(identification) is crossed. Bus %(bus_num) Enclosure %(encl_num) %(identification) Port A cable fault. The drive slot limit exceeded changed from %(old_value) to %(drive_slot_limit_error). The drive slot limit has been exceeded. Power status of the component has changed from %(old_value) to %(power_status). Power status of the component has changed from %(old_value) to %(power_status). Component is currently powered off. Component failed to power up. Compatibility status of the node power supply in %(location) has changed Repair flow Check or replace your SAS cable. Check or replace your SAS cable. - - Replace your cable. - Try rebooting the node. Refer to the Installation and Service Guide for more information on identifying and replacing the faulted component. - System impact SAS connection to the expansion enclosure is degraded. Performance may be impacted. SAS connection to the expansion enclosure is disabled. - - Expansion enclosure is not in service. - - - Performance may be impacted. Performance may be degraded. - Knowledge Base Article - - - - - https://www.dell.com/support /Article/SLN317225 - https://www.dell.com/support /Article/SLN317221 - 44 Dell EMC PowerStore Events and Alerts Reference Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119

Alert and Event Messages
44
Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert raised
Call home
Message
Repair flow
System impact
Knowledge Base Article
from %(old_value) to
%(sas2_cable_status).
0x0030A803
MINOR
TRUE
FALSE
SAS connector B on Bus
%(bus_num) Enclosure
%(encl_num)
%(identification) is
degraded.
Check or replace your SAS
cable.
SAS connection to the
expansion enclosure is
degraded.
Performance
may be impacted.
-
0x0030A804
MINOR
TRUE
FALSE
SAS connector B on Bus
%(bus_num) Enclosure
%(encl_num)
%(identification) is
disabled.
Check or replace your SAS
cable.
SAS connection to the
expansion enclosure is
disabled.
-
0x0030A805
INFO
TRUE
FALSE
SAS connector B on Bus
%(bus_num) Enclosure
%(encl_num)
%(identification) is missing.
-
-
-
0x0030A806
INFO
TRUE
FALSE
SAS connector B on Bus
%(bus_num) Enclosure
%(encl_num)
%(identification) is crossed.
-
-
-
0x0030A807
MAJOR
TRUE
FALSE
Bus %(bus_num)
Enclosure %(encl_num)
%(identification) Port A
cable fault.
Replace your cable.
Expansion enclosure is not
in service.
-
0x0030A901
NONE
FALSE
FALSE
The drive slot limit
exceeded changed from
%(old_value) to
%(drive_slot_limit_error).
-
-
-
0x0030A902
MAJOR
TRUE
FALSE
The drive slot limit has
been exceeded.
-
-
/Article/SLN317225
0x0030AA01
NONE
FALSE
FALSE
Power status of the
component has changed
from %(old_value) to
%(power_status).
-
-
-
0x0030AA02
NONE
FALSE
FALSE
Power status of the
component has changed
from %(old_value) to
%(power_status).
-
-
-
0x0030AA03
MINOR
TRUE
FALSE
Component is currently
powered off.
Try rebooting the node.
Performance may be
impacted.
-
0x0030AA04
MAJOR
TRUE
FALSE
Component failed to power
up.
Refer to the Installation and
Service Guide for more
information on identifying
and replacing the faulted
component.
Performance may be
degraded.
/Article/SLN317221
0x0030AB01
NONE
FALSE
FALSE
Compatibility status of the
node power supply in