Using the Number Editor, Function Keys S1 - S6
![]() |
View all Fluke 8808A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
8808A Users Manual Using the Number Editor Use the number editor to edit the relative base for the relative readings modifier and to set the high and low threshold values for the compare function. Note that you can abort the number editor and return the Meter to normal operation by pressing Q. To use the number editor: 1. Select the number to be edited by pressing the applicable buttons as shown in Table 3-8. The last number entered or value measured is displayed with the leftmost digit bright and the remaining digits dim. (If the number is negative, the minus sign is bright.) Related annunciators are displayed. Buttons Q then V Q then U Q then T Table 3-8. Number Editor Options Number Editor Invoked for Low threshold limit for compare mode High threshold limit for compare mode Relative base for relative readings modifier 2. Press U or V to increment or decrement the highlighted digit to the desired number (from 0 to 9). When the digit is set to the desired number, press S1 through S6 to select the next digit to edit. S1 corresponds to the left-most digit and S6 corresponds to the right-most digit. Repeat this step until you have set all the digits to their desired values. 3. When the value has been set, press C to toggle the sign between positive and negative. If the sign is positive, the negative sign (-) is off. If the sign is negative, the negative sign (-) is on. 4. For Low/High threshold, press R to select the desired range for threshold values. The range goes one step up by pressing R once. If the range reaches the top range, the next press wraps back to range 1 and the value will be cleared. 5. When you are finished editing the number, press and hold R for 2 seconds to store the value. Function Keys S1 - S6 Function keys a through f allow you to save and recall up to six measurement configurations. This helps speed the process of setting up the Meter, and is particularly useful if you repeatedly need the same configurations. To save the present configuration, press Q and then press the function key to which you want to store the configuration. To recall a configuration, press the applicable function key. A beep sounds when the configuration is ready for use, and Setup 8 indicates the number of the latest stored configuration. When a configuration is stored, it includes the following: • Measurement function and initial range on primary display 3-24
![](/manual_guide/products/fluke-8808a-user-manual-567eae0/58.png)