Fluke 8808A User Manual - Page 80
Table 4-10. Function Modifier Commands and Queries cont., Command, Description
View all Fluke 8808A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 80 highlights
8808A Users Manual Table 4-10. Function Modifier Commands and Queries (cont.) Command Description HOLDTHRESH? Meter returns Touch Hold (1, 2, 3, or 4). See "Touch Hold Function (HOLD)" in Chapter 3 for more information. MAX Meter enters MAX modifier with present reading as maximum value. If already in MAX modifier, Meter displays maximum value. In MAX modifier, autoranging is disabled. See "Minimum / Maximum Modifier (MIN MAX)" in Chapter 3 for more information. MAXSET Meter enters MAX modifier with as the maximum value. can be a signed integer, signed real number without exponent, or signed real number with exponent. Autoranging is disabled. See "Minimum / Maximum Modifier (MIN MAX)" in Chapter 3 for more information. If exceeds the measurement range, an Execution Error is generated. MIN Meter enters MIN modifier with present reading as minimum value. If already in MIN modifier, Meter displays minimum value. In MIN modifier, autoranging is disabled. See "Minimum / Maximum Modifier (MIN MAX)" in Chapter 3 for more information. MINSET Meter enters MIN modifier with as the minimum value. can be a signed integer, signed real number without exponent, or signed real number with exponent. Autoranging is disabled. See "Minimum / Maximum Modifier (MIN MAX)" in Chapter 3 for more information. If exceeds the measurement range, an Execution Error is generated. MNMX Meter enters MIN MAX modifier with present reading as minimum and maximum value. If already in MIN MAX modifier, Meter displays latest MIN or MAX value. In MIN MAX modifier, autoranging is disabled. See "Minimum / Maximum Modifier (MIN MAX)" in Chapter 3 for more information. When the MIN MAX modifier is selected, you can toggle between displaying the minimum and maximum readings without losing the minimum and maximum values stored. MNMXSET Meter enters MIN MAX modifier with as the maximum value and as the minimum value. and can be signed integer, signed real number without exponent, or signed real number with exponent. Autoranging is disabled. See "Minimum / Maximum Modifier (MIN MAX)" in Chapter 3 for more information. If or exceeds the measurement range, an Execution Error is generated. MMCLR Meter exits the MN MX modifier. The stored minimum and maximum values are lost, and the Meter returns to the ranging mode and range selected prior to selecting MN MX modifier. 4-20