Install the active Onboard Administrator OA #X in OA bay X.
![]() |
View all HP BladeSystem c3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
Step Step 9 Step 10 Step 11 Step 12 HP BladeSystem c7000 Enclosure Insight Display action and verification Configuration Complete the configuration: 1 Log in to OA #Y using the Administrator account and the new password. 2 Verify that the standby Onboard Administrator (OA #X) firmware is the correct version. 3 Update the active Onboard Administrator firmware, if necessary, to synchronize the firmware on both Onboard Administrators. This update also synchronizes the enclosure settings on the standby Onboard Administrator. 4 Verify the original IP address settings for the standby Onboard Administrator (OA #X). Action Test the OA tray connection: 1 Remove the active Onboard Administrator (OA #X). 2 Reseat the OA tray. 3 Install the active Onboard Administrator (OA #X) in OA bay X. Verification Wait for up to 2 minutes, and then check the Insight Display. • If the Insight Display illuminates and the Insight Display buttons operate, then install the standby Onboard Administrator (OA #Y), if present, in OA bay Y. The repair is complete. • If the issue still exists, then continue to the next step. Action Test the OA tray: 1 Remove the active Onboard Administrator (OA #X). 2 Remove the OA tray and install a service spare or operational OA tray. 3 Install the active Onboard Administrator (OA #X) in OA bay X. Verification Wait for up to 2 minutes, and then check the Insight Display. • If the Insight Display illuminates and the Insight Display buttons operate, then install the standby Onboard Administrator (OA #Y), if present, in OA bay Y. The repair is complete. • If the issue still exists, then continue to the next step. Action Request authorization to remove all devices from device bays 9 and 10. Action Test the Insight Display cable connection: 1 Power down the devices installed in device bays 9 and 10. 2 Remove the devices from device bays 9 and 10. 3 Remove the two screws from the metal plate covering the Insight Display cable connector on the left inside wall of the enclosure. 4 Carefully reseat the Insight Display cable. HP BladeSystem Insight Display troubleshooting 22
![](/manual_guide/products/hewlettpackard-bladesystem-c3000-hp-bladesystem-cclass-enclosure-troubleshooting-guide-041ff57/22.png)