HP BladeSystem c3000 HP BladeSystem c-Class Enclosure Troubleshooting Guide - Page 34
Server blade troubleshooting, Symptoms: Server blade errors
View all HP BladeSystem c3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
Step Step 14 Power supply failure action and verification Verification If the Onboard Administrator health LEDs are green, then the OA tray failed. Continue to the next step. If the power supply fault LEDs are on, then the original OA tray did not fail. Remove all Onboard Administrators and the current OA tray. Install the original OA tray and the Onboard Administrators in the original locations. Continue to the next. Action Contact an HP authorized service provider to complete the midplane assembly replacement (on page 66). Handover in this engagement process an Onboard Administrator SHOW ALL report. Server blade troubleshooting Server blades interact with the enclosure power, cooling, and management infrastructure. This section describes how to troubleshoot a server blade failure inside the enclosure. Other server blade troubleshooting applies to problems that do not involve the enclosure. For all removal and replacement procedures used in this document, see the appropriate server blade maintenance and service guide on the HP website (http://www.hp.com/go/bladesystem/documentation). For specific component LED definitions and component identification, see "Component identification (on page 73)." For server blade LED definitions and component identification, see the server blade user guide or maintenance and service guide on the HP website (http://www.hp.com/go/bladesystem/documentation). Symptoms: Server blade errors Error indication Initial step An Insight Display location error is - reported for this device bay. An Insight Display configuration error - is reported for this device bay. An Insight Display power error is - reported for this device bay. An Insight Display cooling error is - reported for this device bay. An Insight Display device error is - reported for this device bay. A server blade does not power up. - All server blade LEDs are off. Required steps To correct the issue, follow the Insight Display steps. To correct the issue, follow the Insight Display steps. To correct the issue, follow the Insight Display steps. To correct the issue, follow the Insight Display steps. If the Insight Display reports a server blade thermal warning, then check the iLO 2 IML log for specific thermal zone reporting issues. Check that area of the server blade for obstructions and for proper heatsink installation. Examine the reported server blade power LED and health LED. Follow the steps indicated for the specific symptom in this table. Begin with step 1. Enclosure troubleshooting 34