Procedures: Partner blade errors
![]() |
View all HP BladeSystem c3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
Procedures: Partner blade errors CAUTION: Some troubleshooting procedures require powering down an entire enclosure. To avoid possible data loss, always secure permission before powering down an enclosure. CAUTION: If you are using a Virtual Connect environment, some of these procedures might cause the loss of Virtual Connect credentials and the loss of communication between the Onboard Administrator and the Virtual Connect Interconnect module. Ensure the Virtual Connect configuration is backed up before proceeding with any of the following procedures. Virtual Connect configuration can be backed up by using Virtual Connect GUI or Virtual Connect Support Utility. CAUTION: To avoid data loss, do not remove an Onboard Administrator when the Insight Display shows a firmware update in progress. During this activity, the Insight Display displays the Firmware Update screen with the Lock icon and the firmware update progress bar. Step Step 1 Step 2 Step 3 Step 4 Partner blade errors action and verification Action Examine device bay status for the suspect partner blade on the Insight Display Health Summary. Verification If the Insight Display device bay status for the partner blade is black, then continue to the next step. If the Insight Display device bay status for the partner blade is blue, yellow, or red, then follow the Insight Display directions to correct the issue. Action Reseat the partner blade. Verification If the Insight Display device bay status for the partner blade is black, then continue to the next step. If the Insight Display device bay status for the partner blade is blue, yellow, or red, then follow the Insight Display directions to correct the issue. Action Remove the suspect partner blade and install an operational partner blade. Verification If the partner blade health LED is green, then the repair is complete. If the partner blade health LED is off, then the suspect partner blade has not failed. Reinstall the original partner blade: 1 Remove the operational partner blade. 2 Install the original partner blade. 3 Continue to the next step. Action If troubleshooting an HP BladeSystem c7000 Enclosure, then perform the following substeps: 1 Remove all Onboard Administrators. 2 Reseat the OA tray. 3 Install all Onboard Administrators. If troubleshooting an HP BladeSystem c3000 Enclosure, reseat the Onboard Administrator. Enclosure troubleshooting 42
![](/manual_guide/products/hewlettpackard-bladesystem-c3000-hp-bladesystem-cclass-enclosure-troubleshooting-guide-041ff57/42.png)