Processor memory cell components, Interpretation, Fault/UID LED, amber/blue, Online/activity LED

Page 67 highlights

Online/activity LED Fault/UID LED (green) (amber/blue) On Off Flashing (1 Hz) Flashing amber (1Hz) Flashing (1 Hz) Off Flashing irregularly Flashing irregularly Off Off Off Flashing amber (1Hz) Off Solid amber Flashing amber (1Hz) Off Interpretation The drive is online, but is not currently active. CAUTION: Do not remove the drive. Removing a drive can terminate the current operation and cause data loss. The drive is part of an array that is undergoing capacity expansion or stripe migration, but a predictive failure alert has been received for this drive. To minimize the risk of data loss, do not replace the drive until the expansion or migration is complete. CAUTION: Do not remove the drive. Removing a drive can terminate the current operation and cause data loss. The drive is rebuilding, or it is part of an array that is undergoing capacity expansion or stripe migration. The drive is active, but a predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is active and is operating normally. A critical fault condition has been identified for this drive and the controller has placed it offline. Replace the drive as soon as possible. A predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is: offline, a spare, or not configured as part of an array. Processor memory cell components Item Description 1 DIMM slot 1A 2 DIMM slot 2A 3 DIMM slot 3B 4 DIMM slot 4B 5 DIMM slot 5C Processor memory cell components 67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

Interpretation
Fault/UID LED
(amber/blue)
Online/activity LED
(green)
The drive is online, but is not currently active.
Off
On
CAUTION:
Do not remove the drive. Removing a drive can terminate the
current operation and cause data loss.
The drive is part of an array that is undergoing capacity expansion or stripe
migration, but a predictive failure alert has been received for this drive. To
minimize the risk of data loss, do not replace the drive until the expansion
or migration is complete.
Flashing amber
(1Hz)
Flashing (1 Hz)
CAUTION:
Do not remove the drive. Removing a drive can terminate the
current operation and cause data loss.
The drive is rebuilding, or it is part of an array that is undergoing capacity
expansion or stripe migration.
Off
Flashing (1 Hz)
The drive is active, but a predictive failure alert has been received for this
drive. Replace the drive as soon as possible.
Flashing amber
(1Hz)
Flashing
irregularly
The drive is active and is operating normally.
Off
Flashing
irregularly
A critical fault condition has been identified for this drive and the controller
has placed it offline. Replace the drive as soon as possible.
Solid amber
Off
A predictive failure alert has been received for this drive. Replace the drive
as soon as possible.
Flashing amber
(1Hz)
Off
The drive is: offline, a spare, or not configured as part of an array.
Off
Off
Processor memory cell components
Description
Item
DIMM slot 1A
1
DIMM slot 2A
2
DIMM slot 3B
3
DIMM slot 4B
4
DIMM slot 5C
5
Processor memory cell components