HP Indigo 10000 HD Writing Head Service Document - Page 102
Press Service Center > Diagnostics and Troubleshooting > Diagnostics > Writing head
View all HP Indigo 10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 102 highlights
2. Measuring the vacuum level Verify that the new vacuum system is working properly by measuring the Polygon rotation speed, as follows: a. Put the press to Standby mode and wait 15 minutes. b. Select Press Service Center > Diagnostics and Troubleshooting > Diagnostics > Writing head Engine > Run Diagnostics Test > Rotate and run the test. c. After the test completed, go to folder S:\Indigo\bin\eFW\engine d. Find and open file polygonSpeedTestResults_XX.txt and verify that a new line was added (as per the date and time in the line). 100 Appendix D Appendix D - HD writing head spare parts
2.
Measuring the vacuum level
Verify that the new vacuum system is working properly by measuring the Polygon rotation speed, as
follows:
a.
Put the press to Standby mode and wait 15 minutes.
b.
Select
Press Service Center > Diagnostics and Troubleshooting > Diagnostics > Writing head -
Engine > Run Diagnostics Test > Rotate
and run the test.
c.
After the test completed, go to folder
S:\Indigo\bin\eFW\engine
d.
Find and open file
polygonSpeedTestResults_XX.txt
and verify that a new line was added
(as per the date and time in the line).
100
Appendix D
Appendix D - HD writing head spare parts