HP Indigo 10000 HD Writing Head Service Document - Page 20
Crane Safety check, Important Note
View all HP Indigo 10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
27. Connect the transformer power cable. Connect the crane control cable to the transformer. NOTE: The transformer converts the voltage from 115 VAC to 230 VAC. Customers with a 115 VAC power supply may connect the crane without the transformer. 28. Important Note! - Crane Safety check: Before any use the motorized crane you MUST perform the following verifications: a. Check that the crane control buttons match the actual motor movement direction: i. Push the IN button ii. Push the RUN button to activate the motor and make sure that the motor's strap is pulling UP. iii. Push the OUT button iv. Push the RUN button to activate the motor and make sure that the motor's strap is lowering DOWN. 18 Chapter 2 Procedures
27.
Connect the transformer power cable. Connect the crane control cable to the transformer.
NOTE:
The transformer converts the voltage from 115 VAC to 230 VAC. Customers with a 115 VAC
power supply may connect the crane without the transformer.
28.
Important Note!
- Crane Safety check:
Before any use the motorized crane you MUST perform the following verifications:
a.
Check that the crane control buttons match the actual motor movement direction:
i.
Push the
IN
button
ii.
Push the
RUN
button to activate the motor and make sure that the motor’s strap is pulling
UP
.
iii.
Push the
OUT
button
iv.
Push the
RUN
button to activate the motor and make sure that the motor’s strap is
lowering
DOWN
.
18
Chapter 2
Procedures