HP Indigo 10000 HD Writing Head Service Document - Page 63

A. Appendix A - Manually calibrating the scan band with the CPG external tool, S:/Indigo, Screen set

Page 63 highlights

A Appendix A - Manually calibrating the scan band with the CPG external tool Follow these steps to manually calibrate the scan band with the CPG external tool. 1. Put the press in ready mode. 2. Run the ILS Calibration wizard. 3. Copy the CPG SW files to folder: S:/Indigo NOTE: Analyze DA2LP Factors wizard only once per screen per WH. This wizard will usually be performed when installing a new WH. If this is not the first use of the CPG tool on a new WH, skip to Step 9 below. 4. Open file: EilatWHLaserprofiler_CPG_Ver8.exe 5. Select the Screen set you are using. 6. If this is the first time using the CPG tool, select Analyze DA2LP Factors to create the initial configuration files. 7. After the factors analysis is completed, close the CPG tool window. Appendix A - Manually calibrating the scan band with the CPG external tool 61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105

Appendix A - Manually calibrating the scan
band with the CPG external tool
A
Follow these steps to manually calibrate the scan band with the CPG external tool.
1.
Put the press in ready mode.
2.
Run the
ILS Calibration
wizard.
3.
Copy the CPG SW files to folder:
S:/Indigo
NOTE:
Analyze DA2LP Factors
wizard only once per screen per WH. This wizard will usually be
performed when installing a new WH. If this is not the first use of the CPG tool on a new WH, skip to
Step 9 below.
4.
Open file:
EilatWHLaserprofiler_CPG_Ver8.exe
5.
Select the
Screen set
you are using.
6.
If this is the first time using the
CPG tool
, select
Analyze DA2LP Factors
to create the initial
configuration files.
7.
After the factors analysis is completed, close the
CPG tool
window.
Appendix A - Manually calibrating the scan band with the CPG external tool
61