HP Indigo WS6000 Indigo Technical Tips and Workarounds - Page 22

Make sure that when the ILP is, the corona is

Page 22 highlights

c. Verify that air is blowing out of the exhaust chimney when the ILP is working with the corona. d. If a communication error is displayed when trying to activate the corona: An operator may deactivate the ILP (in the Substrate Properties) but the corona remains activated, and when it does not receive the expected PLC feedback signals, a corona communication error is displayed. Make sure that when the ILP is deactivated, the corona is deactivated as well (in the Substrate Properties). 18 Chapter 10 Corona communication errors

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

c.
Verify that air is blowing out of the exhaust chimney when the ILP is working with the corona.
d.
If a communication error is displayed when trying to activate the corona:
An operator may
deactivate
the ILP (in the Substrate Properties) but the corona remains
activated,
and when it does not receive the expected PLC feedback signals, a corona
communication error is displayed.
Make sure that when the ILP is
deactivated
, the corona is
deactivated
as well (in the Substrate
Properties).
18
Chapter 10
Corona communication errors