HP Indigo WS6000 Indigo Technical Tips and Workarounds - Page 41

ILP heater and dryer temperature error, System

Page 41 highlights

20 ILP heater and dryer temperature error System: HP Indigo WS6600 Digital Press with ILP 1. Purpose To describe how to work around an ILP heater and dryer temperature error. 2. Background An ILP heater and dryer temperature error that prevents the ILP from reaching a ready state. 3. Instructions a. Check that the temperature sensor located inside the ILP Heater/Dryer pipe is connected properly; replace the sensor if necessary. ILP heater and dryer temperature error 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

ILP heater and dryer temperature error
20
System:
HP Indigo WS6600 Digital Press with ILP
1.
Purpose
To describe how to work around an ILP heater and dryer temperature error.
2.
Background
An ILP heater and dryer temperature error that prevents the ILP from reaching a ready state.
3.
Instructions
a.
Check that the temperature sensor located inside the ILP Heater/Dryer pipe is connected
properly; replace the sensor if necessary.
ILP heater and dryer temperature error
37