HP Integrity Superdome SX2000 HP Integrity Servers with Microsoft Windows Serv - Page 31
System Management Home SMH
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
2. Download and install the latest Array Configuration Utility (ACU-XE) from www.hp.com/support/itaniumservers. The minimum required revision for the ACU-XE is 7.15.18.0. 3. Download and install the Smart Array Rescan Service from www.hp.com/ support/itaniumservers. The minimum required revision for the Rescan Service is 0.1. 4. If an internal HDD array fails, replace the failed physical drive. The Rescan Service initiates the rebuild automatically (it can take up to 5 minutes before the rebuild starts). To start the rebuild immediately, open the Array Configuration Utility (ACU-XE) and select Refresh in the Controller State field. The failed array begins to rebuild. 640x hot add not supported Issue If a Smart Array 6402 or 6404 card is hot-added to a slot, the card does not function and a yellow exclamation mark displays next to the corresponding device in the Device Manager. Furthermore, any SA640x card added in this manner cannot be safely removed from the system without a reboot. Servers All Integrity Workaround Hot adding is not currently supported for Smart Array 640x on HP Integrity servers. You can use normal hot add procedures to insert the card, but it will not function until the next reboot. Hot add is fully supported on SA530x. 6400 cannot be hot-replaced during error message display Issue The Smart Array 6400 controller cannot be hot-replaced when the following error message appears: The device 'Smart Array 6400' cannot be stopped because a program is still accessing it Servers All Integrity Workaround Restart the Storage Agents service and try to hot-replace the controller again. Command causes machine check abort Issue A machine check abort (MCA) can occur when the reconnect -r command is issued for a Smart Array SA640x with firmware version 2.74 when the server contains multiple SA640x cards with different firmware versions. Servers Superdome SX2000, rx8640, rx7640 Workaround HP recommends you maintain the same firmware version for all Smart Array cards on a server. System Management Homepage (SMH) Software Information page in SMH is blank Issue After upgrading the Integrity Support Pack from Version 6.1 to Version 6.2, the Software Information page in System Management Homepage (SMH) is empty (blank page). Servers All Integrity Workaround 1. Navigate to the C:\CPQSYSTEM\cpxml folder. 2. Remove the cp009280.xml file. 3. Restart SMH. If any pop-up windows display that contain the sw_discovery.exe application name, follow these steps: Troubleshooting Common Issues 31