HP Scanjet 5000 User Guide - Page 88

HP Flexible Smart Array Controller

Page 88 highlights

18. Connect each power cord to the power source. 19. Power up the server (see Powering up the server on page 16). HP Flexible Smart Array Controller CAUTION: HP recommends performing a complete backup of all server data before performing a controller or adapter installation or removal. Before installing the controller, observe the following requirements: ● To ensure cables are connected correctly, observe the labels on the cable and component connectors. ● Be sure you have the latest firmware for the controllers, HBAs, and the expander card. To download the latest firmware, go to the HP website http://www.hp.com/go/hpsc. To install the component: 1. Power down the server (see Powering down the server on page 16). 2. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Do one of the following: ● Extend the server from the rack (see Extending the server from the rack on page 17). ● Remove the server from the rack (see Removing the server from the rack on page 17). 4. Remove the access panel (see Removing the access panel on page 18). 5. Remove the air baffle (see Removing the air baffle on page 25). 6. Install the controller. 7. Connect the appropriate SAS cables. 80 Chapter 5 Hardware options installation

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133

18.
Connect each power cord to the power source.
19.
Power up the server (see
Powering up the server
on page
16
).
HP Flexible Smart Array Controller
CAUTION:
HP recommends performing a complete backup of all server data before performing a controller
or adapter installation or removal.
Before installing the controller, observe the following requirements:
To ensure cables are connected correctly, observe the labels on the cable and component connectors.
Be sure you have the latest firmware for the controllers, HBAs, and the expander card. To download the
latest firmware, go to the HP website
go/hpsc
.
To install the component:
1.
Power down the server (see
Powering down the server
on page
16
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
Extend the server from the rack (see
Extending the server from the rack
on page
17
).
Remove the server from the rack (see
Removing the server from the rack
on page
17
).
4.
Remove the access panel (see
Removing the access panel
on page
18
).
5.
Remove the air baffle (see
Removing the air baffle
on page
25
).
6.
Install the controller.
7.
Connect the appropriate SAS cables.
80
Chapter 5
Hardware options installation