HP Workstation xw6000 Adaptec SCSI RAID 2120S: Software User's Guide - Page 50

Modify, Advanced, Finish., Optionally, click

Page 50 highlights

Adaptec SCSI RAID 2120S/2200S Software User's Guide The following rules apply to migration: 1 The capacity of the new array must match or exceed the capacity of the current array. 2 If the capacity and/or RAID type of the new array requires greater total drive capacity than the current array, the additional capacity must be on drives that are not already used in the current array. To modify an array: 1 Click Modify. 2 Select the array that you wish to modify. 3 Select the RAID level that you want to migrate the array to, or if you want to expand the capacity of the existing array, select the current RAID level. Optionally, click Advanced to select the stripe size you want the new array to use, or that you want to change the existing array to. 4 If necessary, select the additional drive(s) required for capacity expansion, or necessary to support the new RAID level. Optionally, click Advanced to adjust the priority for the task. 5 Click Finish. 3-18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

3-18
Adaptec SCSI RAID 2120S/2200S Software User’s Guide
The following rules apply to migration:
1
The capacity of the new array must match or exceed the
capacity of the current array.
2
If the capacity and/or RAID type of the new array requires
greater total drive capacity than the current array, the
additional capacity must be on drives that are not already used
in the current array.
To modify an array:
1
Click
Modify
.
2
Select the array that you wish to modify.
3
Select the RAID level that you want to migrate the array to, or if
you want to expand the capacity of the existing array, select the
current RAID level.
Optionally, click
Advanced
to select the stripe size you want the
new array to use, or that you want to change the existing array
to.
4
If necessary, select the additional drive(s) required for capacity
expansion, or necessary to support the new RAID level.
Optionally, click
Advanced
to adjust the priority for the task.
5
Click
Finish.