HP Workstation xw6000 Adaptec SCSI RAID 2120S: Software User's Guide - Page 92

read_cache_enable{=boolean}], write_cache_enable{=boolean}] {container}

Page 92 highlights

Adaptec SCSI RAID 2120S/2200S Software User's Guide container restore RAID5 {container} Tries to restore a RAID 5 that has a number of dead segments as members. Parameters {container}-ID of the RAID 5 to restore. container scrub [/io_delay{=integer}] [/no_repair{=boolean}] [/wait{=boolean}] {container} Checks and repairs the consistency of a redundant array (for example, RAID 5 or mirrors). Parameters {container}-ID of the redundant array to build. Switches /io_delay-Number of milliseconds the controller waits between I/Os when building the array. /no_repair-Specifies whether the build operation be performed without repairing the error. /wait-Specifies whether the build operation be performed synchronously or asynchronously. container set cache [/read_cache_enable{=boolean}] [/unprotected{=boolean}] [/write_cache_enable{=boolean}] {container} Sets cache parameters for a specific array. Useful only if a native operating system's file system resides on the array. Parameters {container}-Specifies the ID of the array on which to set cache parameters. Switches /read_cache_enable-Specifies whether to enable the read-ahead cache. /unprotected-Specifies whether to set the container's NVRAM write-back cache to disable, enable when protected, or enable always. Use this switch in conjunction with the /write_cache_enable switch. 4-26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

4-26
Adaptec SCSI RAID 2120S/2200S Software User’s Guide
container restore RAID5 {container}
Tries to restore a RAID 5 that has a number of dead
segments as members.
Parameters
{container}
—ID of the RAID 5 to restore.
container scrub [/io_delay{=integer}]
[/no_repair{=boolean}] [/wait{=boolean}]
{container}
Checks and repairs the consistency of a redundant array (for
example, RAID 5 or mirrors).
Parameters
{container}
—ID of the redundant array to build.
Switches
/io_delay
—Number of milliseconds the controller waits
between I/Os when building the array.
/no_repair
—Specifies whether the build operation be
performed without repairing the error.
/wait
—Specifies whether the build operation be performed
synchronously or asynchronously.
container set cache
[/read_cache_enable{=boolean}]
[/unprotected{=boolean}]
[/write_cache_enable{=boolean}] {container}
Sets cache parameters for a specific array. Useful only if a
native operating system's file system resides on the array.
Parameters
{container}
—Specifies the ID of the array on which to set
cache parameters.
Switches
/read_cache_enable
—Specifies whether to enable the
read-ahead cache.
/unprotected
—Specifies whether to set the container's
NVRAM write-back cache to disable, enable when
protected, or enable always. Use this switch in conjunction
with the
/write_cache_enable